Bombardier Inc. CL-600-2B19 (Regional Jet Series 100) Airworthiness Directives

Browse ADs indexed for this model. Applicability depends on your aircraft configuration.

Check your aircraft configuration

2008-09-12 R1

final rule

Airworthiness Directives; Bombardier, Inc. Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: Failure to preserve critical fuel tank system ignition source prevention features during configuration changes could result in a fuel tank explosion.

Effective: Jan 7, 2010 Category: aircraft Compliance: before further flight
Technical illustration of an aircraft fuel pump, filter, valve, and lines
Problem area Fuel system

2009-23-02

final rule

Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: Excessive wear of the ball screw and ball nut of certain inboard flap actuators could potentially lead to a flap system jam, resulting in a skewed flap condition and reduced controllability of the ...

Effective: Dec 14, 2009 Category: aircraft Compliance: Within 500 flight hours after the effective date of the AD.

2009-10-05

final rule

Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 and 440) Airplanes

Unsafe Condition: Pinion gears in Flap Actuators with part numbers 601R93101-21 and 601R93101-25 lack acceptable certificates of conformance, which could result in flap failure.

Effective: May 28, 2009 Category: aircraft Compliance: Before further flight

2009-06-04

final rule

Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: Insufficient electrical bonding for lightning protection at certain locations inside the fuel tanks could result in arcing and potential ignition source inside the fuel tank during lightning strike...

Effective: Apr 30, 2009 Category: aircraft Compliance: Before further flight
Technical illustration of an aircraft fuel pump, filter, valve, and lines
Problem area Fuel system

2009-06-12

final rule

Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: The Bombardier CL-600-2B19 airplanes have had a history of flap failures at various positions, which may result in a significant increase in required landing distances and higher fuel consumption t...

Effective: Apr 15, 2009 Category: aircraft Compliance: Within 10 flight cycles following the initial on-ground circuit breaker reset operation, or befor...

2008-26-09

final rule

Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: Insufficient electrical bonding between the refuel/defuel shutoff valves and the aircraft structure due to a non-conductive gasket (Gask-O-Seal) and an anodic coating on the shutoff valve electrica...

Effective: Jan 28, 2009 Category: aircraft Compliance: Before further flight
Technical illustration of an aircraft fuel pump, filter, valve, and lines
Problem area Fuel system

2008-23-11 Recurring

final rule

Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: Premature failure of the main landing gear (MLG) main fittings, which could result in collapse of the MLG upon landing.

Effective: Dec 23, 2008 Category: aircraft Compliance: Within 50 flight hours after the effective date of this AD.
Technical illustration of an aircraft landing gear and wheel assembly
Problem area Landing gear

2008-22-03

final rule

Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: Potential ignition sources inside the fuel system could result in a fuel tank explosion.

Effective: Nov 28, 2008 Category: aircraft Compliance: Within the compliance times specified in the revised maintenance requirements manual.
Technical illustration of an aircraft fuel pump, filter, valve, and lines
Problem area Fuel system

2008-21-09

final rule

Airworthiness Directives; Bombardier Model CL-600-1A11 (CL-600), CL-600-2A12 (CL-601), CL-600-2B16 (CL-601-3A, CL-601-3R, & CL-604 (Including CL-605 Marketing Variant)) Airplanes, and Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: Reports of uncommanded roll during take-off resulting from even small amounts of frost, ice, snow, or slush on the wing leading edges or forward upper wing surfaces.

Effective: Oct 31, 2008 Category: aircraft Compliance: Within 12 months of the effective date (October 31, 2008).

2008-12-10

final rule

Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: The electrical harness of the Fuel Quantity Gauging System (FQGS) is installed in the same routing as 28 Volts AC, 28 Volts DC, and 115 Volts AC electrical harnesses, which could lead to chafing an...

Effective: Jul 16, 2008 Category: aircraft Compliance: Before further flight
Technical illustration of an aircraft fuel pump, filter, valve, and lines
Problem area Fuel system

2008-06-10 Recurring

final rule

Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: Cracking of the left side and right side frame and reinforcement angles at fuselage station (FS) 640 between stringer 9 and stringer 12, which could lead to failure of the fuselage structure and po...

Effective: Apr 16, 2008 Category: aircraft Compliance: Before further flight
Technical illustration of a riveted aircraft structural panel and frame
Problem area Airframe structure

2008-05-13

final rule

Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: Short circuit failures of certain AC contactors located in the avionics bay, which could result in arcing and consequent smoke or fire.

Effective: Apr 8, 2008 Category: aircraft Compliance: Before further flight.
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system

2008-04-08

final rule

Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: unsafe condition on an aviation product.

Effective: Mar 28, 2008 Category: aircraft

2008-03-19

final rule

Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: unsafe condition on an aviation product.

Effective: Mar 17, 2008 Category: aircraft

2008-02-07

final rule

Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: unsafe condition on an aviation product.

Effective: Feb 26, 2008 Category: aircraft

2007-15-02

final rule

Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: Exceeded backlash in both aileron power control units (PCUs), which, if accompanied by the failure of the flutter damper, could result in aileron vibration/flutter and reduced controllability of th...

Effective: Aug 28, 2007 Category: aircraft Compliance: Within 12 months of the effective date of the AD (August 28, 2007).
Technical illustration of an aircraft flight control surface and actuator
Problem area Flight controls

2007-04-24 Recurring

final rule

Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: Missing or fractured bolts attaching the exhaust nozzle to the aft engine flange could lead to the loss of the engine exhaust nozzle in flight, causing structural damage to the airplane and potenti...

Effective: Apr 3, 2007 Category: engine Compliance: Before further flight

2007-05-11

final rule

Airworthiness Directives; Bombardier Model CL-600-2B16 (CL-604) Airplanes and Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: Reports of trim problems including uncommanded trim, trim in the opposite direction to that selected, loss of trim position indication, and potential loss of trim disconnect capability.

Effective: Mar 20, 2007 Category: aircraft Compliance: Before further flight.

2007-03-19 Recurring

final rule

Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: Stress analyses have shown that certain main fittings of the main landing gears (MLGs) are susceptible to premature cracking, starting in the radius of the upper lug, which could result in failure ...

Effective: Mar 15, 2007 Category: aircraft Compliance: Before further flight.

2007-03-11

final rule

Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: Incorrect installation of the release pin into the safety pin hole of the activation mechanism of the chemical oxygen generator can result in failure to activate the generator when required. A sepa...

Effective: Mar 12, 2007 Category: aircraft Compliance: Before further flight
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system

2007-01-07 Recurring

final rule

Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: Fatigue cracking of the main fitting of the main landing gear (MLG), which could result in the collapse of the MLG.

Effective: Feb 16, 2007 Category: aircraft Compliance: Within 50 flight hours after the effective date of this AD.
Technical illustration of an aircraft landing gear and wheel assembly
Problem area Landing gear

2006-12-21

final rule

Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: Failure of the flap system, resulting in a twisted outboard flap panel, which could lead to flap asymmetry and reduced controllability of the airplane.

Effective: Jul 21, 2006 Category: aircraft Compliance: Within 12 months of the effective date (July 21, 2006).

2006-11-09

final rule

Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: A crack was discovered at the lower forward corner of a cargo door skin cut-out during fatigue testing, which could result in reduced structural integrity of the airplane.

Effective: Jun 30, 2006 Category: aircraft Compliance: Within 30 days after the effective date of the AD.

2006-10-06

final rule

Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 and 440) Airplanes

Unsafe Condition: Defective Leach TDH-series electrical relays affecting emergency equipment, including the passenger oxygen system, thrust reverse control system, and auxiliary power unit fire detection, warning, a...

Effective: Jun 16, 2006 Category: aircraft Compliance: Within 5,500 flight hours or 36 months after the effective date of the AD, whichever is first.

2006-10-01 Recurring

final rule

Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: Failure of the fire and overheat control unit due to potential damage from environmental factors.

Effective: Jun 12, 2006 Category: aircraft Compliance: Before further flight