Bombardier Inc. CL-600-2B19 (Regional Jet Series 100) Airworthiness Directives

Browse ADs indexed for this model. Applicability depends on your aircraft configuration.

Check your aircraft configuration

2013-14-11

final rule

Airworthiness Directives; Bombardier, Inc. Airplanes

Unsafe Condition: Failure of the voltage regulator inside the yaw damper actuator could lead to uncommanded yaw movement, which could result in the loss of the ability to control the airplane.

Effective: Aug 9, 2013 Category: aircraft Compliance: Within 50 flight hours after the effective date of this AD.

2013-01-01

final rule

Airworthiness Directives; Bombardier, Inc. Airplanes

Unsafe Condition: Hydraulic accumulator screw cap/end cap failure, which could result in the loss of the associated hydraulic system and high-energy impact damage to adjacent systems and structure, and consequent lo...

Effective: Jul 23, 2013 Category: aircraft Compliance: Within 60 days of the effective date of this AD.

2013-09-07

final rule

Airworthiness Directives; Bombardier, Inc. Airplanes

Unsafe Condition: Incorrect installation of the upper bolt in the main landing gear (MLG) uplock assembly, which could prevent the MLG from extending and could adversely affect the safe landing of the airplane.

Effective: Jun 18, 2013 Category: aircraft Compliance: Within 5,500 flight hours or 48 months after the effective date of this AD, whichever occurs first.
Technical illustration of an aircraft landing gear and wheel assembly
Problem area Landing gear

2013-03-22

final rule

Airworthiness Directives; Bombardier, Inc. Airplanes

Unsafe Condition: Cargo compartment liners installed on CL-600-2B19 airplanes configured with a Class C cargo compartment do not meet flammability requirements, potentially leading to inadequate fire protection and ...

Effective: Apr 17, 2013 Category: aircraft Compliance: Within 28 months after the effective date of the AD.

2011-21-07 R1

final rule

Airworthiness Directives; Bombardier, Inc. Airplanes

Unsafe Condition: Pitot-static tubing may become partially or completely blocked by water, resulting in erroneous airspeed and altitude indications and consequent loss of control of the airplane.

Effective: Dec 18, 2012 Category: aircraft Compliance: before further flight

2012-21-14

final rule

Airworthiness Directives; Bombardier, Inc. Airplanes

Unsafe Condition: Failure of the main landing gear (MLG) side brace fitting shaft due to corrosion could result in collapse of the main landing gear.

Effective: Dec 5, 2012 Category: aircraft Compliance: before further flight
Technical illustration of an aircraft landing gear and wheel assembly
Problem area Landing gear

2012-16-15

final rule

Airworthiness Directives; Bombardier, Inc. Airplanes

Unsafe Condition: Jamming/malfunctioning of the left-hand engine thrust control mechanism due to an improperly stowed or dislodged upper core-cowl-door Hold Open Rod obstructing the movement of the Fuel Control Unit...

Effective: Sep 25, 2012 Category: engine Compliance: Within 36 months or 6,000 flight hours after the effective date of this AD, whichever occurs first.

2012-13-03

final rule

Airworthiness Directives; Bombardier, Inc. Airplanes

Unsafe Condition: Damage to the third crew person oxygen line and oxygen escaping from it, which could feed a fire in the vicinity of an electrical panel.

Effective: Aug 2, 2012 Category: aircraft Compliance: Within 4,000 flight hours after the effective date of the AD.

2012-08-04

final rule

Airworthiness Directives; Bombardier, Inc. Airplanes

Unsafe Condition: The air driven generator (ADG) failing to power essential buses during functional tests, due to the low threshold setting of the circuit protection on the ADG's generator control unit (GCU) prevent...

Effective: May 29, 2012 Category: aircraft Compliance: Within 24 months after the effective date of this AD.
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system

2011-18-08

final rule

Airworthiness Directives; Bombardier, Inc. Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: Arcing of chafed integrated drive generator (IDG) power cables due to inadequate clearance caused by broken hydraulic line support brackets at fuselage station (FS) 672, potentially leading to an u...

Effective: Sep 9, 2011 Category: aircraft Compliance: Within 45 days after the effective date
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system

2011-07-06

final rule

Airworthiness Directives; Bombardier, Inc. Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: The FAA is correcting an airworthiness directive (AD) that published in the Federal Register. That AD applies to the products listed above. The service information reference in paragraph (g)(7) in ...

Effective: May 24, 2011 Category: aircraft Compliance: Before further flight

2011-06-08

final rule

Airworthiness Directives; Bombardier, Inc. Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes, CL-600-2C10 (Regional Jet Series 700, 701, & 702) Airplanes, CL-600-2D15 (Regional Jet Series 705) Airplanes, and CL-600-2D24 (Regional Jet Series 900) Airplanes

Unsafe Condition: Failures of the harness assembly (power feeder wires) connecting the Air-Driven Generator (ADG) to the aeroplane electrical system, in the area close to the ADG cannon plug, due to corrosion and be...

Effective: Apr 26, 2011 Category: aircraft Compliance: Within 72 months or 6,000 flight hours, whichever occurs first.
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system

2011-05-03

final rule

Airworthiness Directives; Bombardier, Inc. Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: Numerous reported failures of the Regional Jet engine TCGB (P/Ns: 2100140-003, 2100140-005, 2100140-007) have occurred, some resulting in in-flight engine shutdowns. Post-incident investigations re...

Effective: Mar 31, 2011 Category: aircraft Compliance: Before further flight

2011-04-03

final rule

Airworthiness Directives; Bombardier, Inc. Model CL-600-2B19 (Regional Jet Series 100 and 440) Airplanes

Unsafe Condition: Wing leading edge thermal switches Part Number 601R59320-1 are not detecting bleed leaks at the design threshold, potentially leading to dormant failure and compromising wing leading edge structura...

Effective: Mar 22, 2011 Category: aircraft Compliance: Within 30 days after the effective date of the AD

2010-23-14

final rule

Airworthiness Directives; Bombardier, Inc. Model CL-600-2B19 (Regional Jet Series 100 & 440), CL-600-2C10 (Regional Jet Series 700, 701 & 702), CL-600-2D15 (Regional Jet Series 705), and CL-600-2D24 (Regional Jet Series 900) Airplanes

Unsafe Condition: Corrosion in lower structural members of the passenger door due to deterioration of a drainage ramp retaining moisture.

Effective: Dec 22, 2010 Category: aircraft Compliance: Before further flight

2010-21-11

final rule

Airworthiness Directives; Bombardier, Inc. Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: A specific batch of nose landing gear (NLG) and NLG door selector valves, part number (P/N) 601R75146-1 (Kaiser Fluid Technologies P/N 750006000), may have had their end caps incorrectly lock-wired...

Effective: Nov 18, 2010 Category: aircraft Compliance: Within 1,600 flight hours or 18 months after the effective date of this AD, whichever occurs first.
Technical illustration of an aircraft landing gear and wheel assembly
Problem area Landing gear

2010-20-17

final rule

Airworthiness Directives; Bombardier, Inc. Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: Three cases of in-flight loss of cabin pressurization have been reported, resulting from failure of a bulkhead check valve in combination with failure of an air supply duct.

Effective: Nov 9, 2010 Category: aircraft Compliance: Before further flight
Technical illustration of a riveted aircraft structural panel and frame
Problem area Airframe structure

2010-20-19

final rule

Airworthiness Directives; Bombardier, Inc. Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes; Model CL-600-2C10 (Regional Jet Series 700, 701, & 702) Airplanes; Model CL-600-2D15 (Regional Jet Series 705) Airplanes; and Model CL-600-2D24 (Regional Jet Series 900) Airplanes

Unsafe Condition: Crack on a 'dry' ADG (Hamilton Sundstrand part number in the 761339 series) in the aft area of the strut and generator housing assembly, due to a manufacturing anomaly with wall thickness below spe...

Effective: Nov 5, 2010 Category: aircraft Compliance: Before further flight

2010-20-09

final rule

Airworthiness Directives; Bombardier, Inc. Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes; Model CL-600-2C10 (Regional Jet Series 700, 701, & 702) Airplanes; Model CL-600-2D15 (Regional Jet Series 705) and Model CL-600-2D24 (Regional Jet Series 900) Airplanes

Unsafe Condition: Failure of balance washer screws due to metallographic non-conformity, leading to turbine imbalance and potential ADG structural failure, loss of electrical power, structural damage to the aircraft...

Effective: Nov 1, 2010 Category: aircraft Compliance: Within the applicable time in paragraph (g) or (h) of the AD.

2010-17-17

final rule

Airworthiness Directives; Bombardier, Inc. Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: Stick Pusher Capstan Shaft failures causing severe degradation of the stick pusher function.

Effective: Sep 29, 2010 Category: aircraft Compliance: Within 30 days after the effective date of this AD for AFM revisions; within 500 flight hours aft...

2010-14-03

final rule

Airworthiness Directives; Bombardier, Inc. Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: Failure of the Air-Driven Generators (ADGs) due to a wiring anomaly that could cause a short circuit between internal wires and metallic over-braided shields, leading to the ADG not providing power...

Effective: Aug 4, 2010 Category: aircraft Compliance: Within 50 flight hours after the effective date of the AD.
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system

2010-09-10

final rule

Airworthiness Directives; Bombardier, Inc. Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: The overwing emergency exit placards illustrate an incorrect hand position for removal of the exit upper handle cover, which could cause difficulty or delay when opening the overwing emergency exit.

Effective: Jun 3, 2010 Category: aircraft Compliance: Within 12 months after April 4, 2010.

2010-08-03

final rule

Airworthiness Directives; Bombardier, Inc. Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: The heating capability of several Angle Of Attack (AOA) transducer heating elements is below the minimum requirement, and a large number of AOA transducers repaired in an approved maintenance facil...

Effective: May 19, 2010 Category: aircraft Compliance: Before further flight

2009-22-05

final rule

Airworthiness Directives; Bombardier, Inc. Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: Cracked wing leading edge anti-ice piccolo ducts manufactured since May 2000, due to the drilling process, may cause air leakage, affecting anti-ice air distribution and anti-ice capability without...

Effective: Apr 15, 2010 Category: aircraft Compliance: Within 12 months of the effective date (April 15, 2010).

2010-05-14

final rule

Airworthiness Directives; Bombardier, Inc. Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition: Resolver stators installed in AOA transducers were not cleaned correctly, degrading transducer performance at low temperatures and causing freezing of the resolver, which may provide inaccurate AOA...

Effective: Mar 24, 2010 Category: aircraft Compliance: Before further flight