AD 2006-10-01
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Bombardier Inc. | CL-600-2B19 (Regional Jet Series 100) | Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes |
| aircraft | Bombardier Inc. | CL-600-2B19 (Regional Jet Series 440) | Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes |
Unsafe Condition
Failure of the fire and overheat control unit due to potential damage from environmental factors.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Install protective tape on the fire and overheat control unit. Conduct repetitive inspections of the protective tape's condition and take corrective action as necessary. Eventually replace the existing fire and overheat control unit with a modified unit.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) airplanes.
AI-generated summary from the source AD text. Verify against the official source before acting.
Federal Register Abstract
This document corrects a typographical error that appeared in AD 2006-10-01 that was published in the Federal Register on May 8, 2006 (71 FR 26682). The typographical error resulted in an incorrect revision date for a referenced service bulletin. This AD is applicable to certain Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) airplanes. This AD requires the installation of protective tape on the fire and overheat control unit in the flight compartment, and repetitive inspections of the condition of the protective tape and related corrective action. This AD also mandates eventual replacement of the existing fire and overheat control unit with a modified unit, which ends the repetitive inspections.
Document Text
Show stored source text (verify against official source)
[Federal Register Volume 71, Number 112 (Monday, June 12, 2006)]
[Rules and Regulations]
[Page 33614]
From the Federal Register Online via the Government Publishing Office [<a href="http://www.gpo.gov">www.gpo.gov</a>]
[FR Doc No: 06-5246]
-----------------------------------------------------------------------
DEPARTMENT OF TRANSPORTATION
Federal Aviation Administration
14 CFR Part 39
[Docket No. 2003-NM-233-AD; Amendment 39-14585; AD 2006-10-01]
RIN 2120-AA64
Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional
Jet Series 100 & 440) Airplanes
AGENCY: Federal Aviation Administration, DOT.
ACTION: Final rule; correction.
-----------------------------------------------------------------------
SUMMARY: This document corrects a typographical error that appeared in
AD 2006-10-01 that was published in the Federal Register on May 8, 2006
(71 FR 26682). The typographical error resulted in an incorrect
revision date for a referenced service bulletin. This AD is applicable
to certain Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440)
airplanes. This AD requires the installation of protective tape on the
fire and overheat control unit in the flight compartment, and
repetitive inspections of the condition of the protective tape and
related corrective action. This AD also mandates eventual replacement
of the existing fire and overheat control unit with a modified unit,
which ends the repetitive inspections.
DATES: Effective June 12, 2006.
FOR FURTHER INFORMATION CONTACT: Rocco Viselli (or James Delisio),
Aerospace Engineer, Airframe and Propulsion Branch, ANE-171, FAA, New
York Aircraft Certification Office, 1600 Stewart Avenue, suite 410,
Westbury, New York; telephone (516) 228-7331 (or (516) 228-7321); fax
(516) 794-5531.
SUPPLEMENTARY INFORMATION: Airworthiness Directive (AD) 2006-10-01,
amendment 39-14585, applicable to certain Bombardier Model CL-600-2B19
(Regional Jet Series 100 & 440) airplanes, was published in the Federal
Register on May 8, 2006 (71 FR 26682). That AD requires the
installation of protective tape on the fire and overheat control unit
in the flight compartment, and repetitive inspections of the condition
of the protective tape and related corrective action. That AD also
mandates eventual replacement of the existing fire and overheat control
unit with a modified unit, which ends the repetitive inspections.
As published, the AD reads throughout, ``Bombardier Alert Service
Bulletin A601R-26-017, Revision ``C,'' dated November 6, 2003.'' The
correct date of the service bulletin revision should be November 3,
2003.
Since no other part of the regulatory information has been changed,
the final rule is not being republished in the Federal Register.
The effective date of this AD remains June 12, 2006.
Sec. 39.13 [Corrected]
On page 26685, in the left-hand column, paragraph (g) of AD 2006-
10-01 is corrected to read as follows:
* * * * *
(g) Actions accomplished before the effective date of this AD in
accordance with Bombardier Alert Service Bulletin A601R-26-017,
Revision `C,' dated November 3, 2003; and Bombardier Service
Bulletin 601R-26-018, dated December 2, 2002; or Revision `A,' dated
February 27, 2003; as applicable; are considered acceptable for
compliance with the corresponding requirements of this AD.
* * * * *
Issued in Renton, Washington, on May 31, 2006.
Kalene C. Yanamura,
Acting Manager, Transport Airplane Directorate, Aircraft Certification
Service.
[FR Doc. 06-5246 Filed 6-9-06; 8:45 am]