AD 2012-08-04

final rule
Data completeness: 70%

Airworthiness Directives; Bombardier, Inc. Airplanes

AD Number
2012-08-04
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. FAA-2011-1224
FR Citation
77 FR 24362

Applicability

TypeManufacturerModelDetails
aircraft Bombardier Various Airworthiness Directives; Bombardier, Inc. Airplanes

Unsafe Condition

The air driven generator (ADG) failing to power essential buses during functional tests, due to the low threshold setting of the circuit protection on the ADG's generator control unit (GCU) preventing the ADG from supplying power to the essential buses.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Remove the ADG GCU, Bombardier part number (P/N) 604-90800-7 (Hamilton Sundstrand P/N 761341A), and install a new or serviceable ADG GCU, Bombardier P/N 604-90800-27 (Hamilton Sundstrand P/N 761341B), in accordance with the Accomplishment Instructions of Bombardier Service Bulletin 601R-24-130.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within 24 months after the effective date of this AD.

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Bombardier, Inc. Model CL-600-2B19 (Regional Jet Series 100 & 440) airplanes, certificated in any category, serial numbers 7305 through 7990 inclusive, and 8000 through 8109 inclusive.