Airworthiness Directives; Bombardier, Inc. Airplanes

AD Number
2013-14-11
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. FAA-2013-0623
FR Citation
78 FR 44871

Applicability

TypeManufacturerModelDetails
aircraft Bombardier Various Airworthiness Directives; Bombardier, Inc. Airplanes

Unsafe Condition

Failure of the voltage regulator inside the yaw damper actuator could lead to uncommanded yaw movement, which could result in the loss of the ability to control the airplane.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Revise the airplane flight manual (AFM) by incorporating an emergency procedure for uncommanded yaw motion.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within 50 flight hours after the effective date of this AD.

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Bombardier, Inc. Model CL-600-2B19 (Regional Jet Series 100 & 440), CL-600-2C10 (Regional Jet Series 700, 701, & 702), CL-600-2D15 (Regional Jet Series 705), and CL-600-2D24 (Regional Jet Series 900) airplanes.

AI-generated summary from the source AD text. Verify against the official source before acting.