AD 2010-14-03
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Bombardier | Various | Airworthiness Directives; Bombardier, Inc. Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes |
| aircraft | Aviat | Various | Airworthiness Directives; Bombardier, Inc. Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes |
Unsafe Condition
Failure of the Air-Driven Generators (ADGs) due to a wiring anomaly that could cause a short circuit between internal wires and metallic over-braided shields, leading to the ADG not providing power when deployed.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Inspect the Air-Driven Generators (ADGs) for the specified wiring anomaly. Replace or revise the ADGs as necessary to correct the wiring issue. Revise the maintenance program to include periodic inspections of the ADGs for the identified wiring anomaly.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 50 flight hours after the effective date of the AD.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Bombardier, Inc. Model CL-600-2B19 (Regional Jet Series 100 & 440) airplanes, serial numbers 7305 through 8102.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain
This site is not affiliated with or endorsed by the FAA. Always verify with official sources.