2004-02-06

final rule

Airworthiness Directives; McDonnell Douglas Model DC-10-10, DC-10-10F, DC-10-15, DC-10-30, DC-10-30F, DC-10-30F (KC-10A- and KDC-10), DC-10-40, DC-10-40F, MD-10-10F, and MD-10-30F Airplanes; and Model MD-11 and MD-11F Airplanes

Unsafe Condition: Cracking in the nuts on the lower attach bolt assemblies of the forward attach bracket of the inboard flap outboard hinge could lead to separation of the inboard flap outboard hinge from the wing s...

Effective: Mar 5, 2004 Category: aircraft Compliance: Before further flight

2004-01-19

final rule

Airworthiness Directives; McDonnell Douglas Model MD-11 and -11F Airplanes

Unsafe Condition: Arcing of the wire assembly connectors of the overhead storage bin, service module, and bin extension assemblies, which could lead to smoke/fire in the cabin.

Effective: Feb 24, 2004 Category: aircraft Compliance: Before further flight.
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system

2004-01-18

final rule

Airworthiness Directives; McDonnell Douglas Model MD-11 and -11F Airplanes

Unsafe Condition: Failure of the vent fan wiring in the right forward cabin drop ceiling, right mid cabin drop ceiling, or right forward cargo compartment could result in fire and/or smoke.

Effective: Feb 24, 2004 Category: aircraft Compliance: Before further flight.
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system

2004-01-16

final rule

Airworthiness Directives; McDonnell Douglas Model MD-11 and -11F Airplanes

Unsafe Condition: Omission of the phrase 'as applicable' in AD 2004-01-16 led to incomplete wire connection stackups for the generator feeder tail compartment of the auxiliary power unit (APU) and potential issues w...

Effective: Feb 24, 2004 Category: aircraft Compliance: Not specified in the provided text.
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system

2003-25-10

final rule

Airworthiness Directives; McDonnell Douglas Model MD-11 and -11F Airplanes

Unsafe Condition: Chafing or damage of electrical wires leading to terminal strips in the center accessory compartment (CAC) area, which could result in arcing and sparking damage to power feeder cables, terminal st...

Effective: Jan 27, 2004 Category: aircraft Compliance: Within 12 months after the effective date of this AD

2003-24-10

final rule

Airworthiness Directives; McDonnell Douglas Model DC-10-10, DC-10-10F, DC-10-15, DC-10-30, DC-10-30F, DC-10-30F (KC10A and KDC-10), DC-10-40, DC-10-40F, MD-10-10F, MD-10-30F, MD-11, and MD-11F Airplanes

Unsafe Condition: Failure of the rudder pedal arm assembly, which could result in reduced controllability of the airplane.

Effective: Jan 8, 2004 Category: aircraft Compliance: Before further flight
Technical illustration of an aircraft flight control surface and actuator
Problem area Flight controls

2003-24-09

final rule

Airworthiness Directives; McDonnell Douglas Model MD-11 and -11F Airplanes

Unsafe Condition: Chafing and arcing of the parallel feeder cables of the number 2 integrated drive generator (IDG), which could result in smoke and/or fire in the right aft galley area.

Effective: Jan 8, 2004 Category: aircraft Compliance: Within 6 months after the effective date of this AD or AD 2001-17-08, depending on the group of a...
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system

2003-03-15 R1

final rule

Airworthiness Directives; Various Boeing and McDonnell Douglas Transport Category Airplanes

Unsafe Condition: Incapacitation of the flightcrew due to lack of oxygen could result in loss of control of the airplane.

Effective: Dec 22, 2003 Category: aircraft Compliance: Effective December 22, 2003.

2003-22-08

final rule

Airworthiness Directives; McDonnell Douglas Model MD-11 and -11F Airplanes

Unsafe Condition: Corrosion of the barrel nut holes of the upper spar caps and skin panel of the horizontal stabilizer, which could result in structural damage and consequent reduced controllability of the airplane.

Effective: Dec 8, 2003 Category: aircraft Compliance: Within 18 months or 6,000 flight hours after the effective date, whichever is later.
Technical illustration of a riveted aircraft structural panel and frame
Problem area Airframe structure

2003-21-10

final rule

Airworthiness Directives; McDonnell Douglas Model MD-11 and -11F Airplanes

Unsafe Condition: Arcing damage of the terminal strips, surrounding structure, and electrical cables in the forward cargo compartment can lead to damage to the terminal strips and adjacent structure, and potentially...

Effective: Nov 26, 2003 Category: aircraft Compliance: Within 18 months after the effective date of this AD

2003-21-05

final rule

Airworthiness Directives; McDonnell Douglas Model MD-11 Airplanes

Unsafe Condition: The wire bundle contained in the feed-through contacting the bottom of the feed-through, which could cause cable chafing, electrical arcing, and smoke or fire in the cockpit.

Effective: Nov 21, 2003 Category: aircraft Compliance: Within 1 year after the effective date of this AD
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system

2003-17-12

final rule

Airworthiness Directives; McDonnell Douglas Model MD-11 and MD-11F Airplanes

Unsafe Condition: Internal overheating and arcing of circuit breakers and airplane wiring due to long-term use and breakdown of internal components of the circuit breakers, which could result in smoke and fire in th...

Effective: Oct 7, 2003 Category: aircraft Compliance: Within 24 months after the effective date of the AD.
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system

2003-17-07 R1

final rule

Airworthiness Directives; Various Transport Category Airplanes Manufactured by McDonnell Douglas

Unsafe Condition: Failure of the fire extinguishers for the engine and auxiliary power unit (APU) to fire discharge cartridges, which could result in the inability to put out a fire in an engine or in the APU.

Effective: Sep 24, 2003 Category: aircraft Compliance: before further flight

2003-16-01

final rule

Airworthiness Directives; McDonnell Douglas Model MD-11 and -11F Airplanes

Unsafe Condition: Overheating and internal component failure of the dimmer control unit of the overhead instrument lighting, which could result in smoke and/or fire in the flight compartment.

Effective: Sep 12, 2003 Category: aircraft Compliance: Before further flight.

2003-08-09

final rule

Airworthiness Directives; McDonnell Douglas Model MD-11 and -11F Airplanes

Unsafe Condition: Improper wire installations during manufacture and/or maintenance may lead to electrical arcing and/or heat-damaged wires, potentially causing fire and smoke in various areas of the airplane.

Effective: May 27, 2003 Category: aircraft Compliance: Within 50 flight hours after the effective date of this AD.
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system

2003-08-08

final rule

Airworthiness Directives; McDonnell Douglas Model MD-11 and -11F Airplanes

Unsafe Condition: Chafing of electrical wire assemblies above the forward passenger doors and above the entry door (L1) sliding panel of the forward drop ceiling on the passenger compartment, which could result in e...

Effective: May 27, 2003 Category: aircraft Compliance: Not specified in the provided text.
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system

2003-04-16

final rule

Airworthiness Directives; McDonnell Douglas Model MD-11 and MD-11F Airplanes

Unsafe Condition: Chafed wires in the avionics equipment compartment due to maintenance personnel lying against the removed cover and/or insulation blankets that cover wire harnesses, which could lead to smoke and/o...

Effective: May 27, 2003 Category: aircraft Compliance: Not specified in the provided text.
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system

2003-04-17

final rule

Airworthiness Directives; McDonnell Douglas Model MD-11 and MD-11F Airplanes

Unsafe Condition: Damage to wiring/bundles routed to the wire support bar of the circuit breaker panel and to the circuit breakers, along with incorrect routing, could lead to chafing and consequent arcing or loss o...

Effective: May 27, 2003 Category: aircraft Compliance: Before further flight
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system

2003-08-14

final rule

Airworthiness Directives; McDonnell Douglas Model DC-10-10, DC-10-10F, DC-10-15, DC-10-30, DC-10-30F, DC-10-30F (KC10A and KDC-10), DC-10-40, DC-10-40F, MD-10-10F, MD-10-30F, MD-11, and MD-11F Airplanes

Unsafe Condition: Electrical arcing in the connector for a fuel boost/transfer pump, which could result in a fire or explosion of a fuel tank.

Effective: May 12, 2003 Category: aircraft Compliance: Not specified in the provided text.
Technical illustration of an aircraft fuel pump, filter, valve, and lines
Problem area Fuel system

2002-23-18

final rule

Airworthiness Directives; McDonnell Douglas Model MD-11 and -11F Airplanes Equipped with Collins LRA-900 Radio Altimeters

Unsafe Condition: A fault in Collins LRA-900 radio altimeters having a certain part number could result in an incorrect and unbounded output of radio altitude to other airplanes, leading to an undetected anomalous r...

Effective: Dec 31, 2002 Category: aircraft Compliance: Within 90 days after the effective date of this AD.
Technical illustration of an aircraft flight control surface and actuator
Problem area Flight controls

2002-14-04

final rule

Airworthiness Directives; McDonnell Douglas Model MD-11 and -11F Airplanes

Unsafe Condition: Chafing on adjacent structure and damaged wiring of the Firex bottle discharge cartridge of the No. 2 engine at station Y=2163.00 bulkhead, which could result in improper distribution of the fire e...

Effective: Aug 23, 2002 Category: engine Compliance: Before further flight.

2002-14-10

final rule

Airworthiness Directives; McDonnell Douglas Model MD-11 and -11F Airplanes Equipped With United Technologies Pratt & Whitney Engines

Unsafe Condition: Arcing of the integrated drive generator (IDG) wire harness, which could result in smoke and/or fire in the area of the forward engine mount bolt retainer and/or fire detector responder.

Effective: Aug 23, 2002 Category: engine Compliance: Before further flight.

2002-14-14

final rule

Airworthiness Directives; McDonnell Douglas Model MD-11 and -11F Airplanes Equipped With General Electric Tail Engine Buildup Units (EBU)

Unsafe Condition: Inadequate support of the wire harness of the integrated drive generator (IDG) could result in chafing and arcing, leading to smoke and/or fire in the area of the forward engine mount.

Effective: Aug 23, 2002 Category: engine Compliance: Before further flight.

2002-14-06

final rule

Airworthiness Directives; McDonnell Douglas Model MD-11 and -11F Airplanes

Unsafe Condition: Lack of protective sleeving on the right emergency AC wire assembly of the overhead switch panel could result in loss of redundant electrical power during certain cockpit overhead wiring faults.

Effective: Aug 23, 2002 Category: aircraft Compliance: Before further flight.
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system

2002-14-13

final rule

Airworthiness Directives; McDonnell Douglas Model MD-11 and -11F Airplanes

Unsafe Condition: Failure of the wire assemblies and damage of a ballast of a light fixture, which could result in smoke and/or fire in the forward cargo compartment.

Effective: Aug 23, 2002 Category: aircraft Compliance: Before further flight.
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system