Hamilton Standard Propeller Blades Airworthiness Directives

Browse ADs indexed for this model. Applicability depends on your aircraft configuration.

Check your aircraft configuration

58-19-02

final rule

HAMILTON STANDARD Propellers

Unsafe Condition: The 2J17 Series propeller blades require exceptional maintenance procedures and repair techniques to ensure continued airworthiness, as indicated by adverse experiences.

Category: appliance Compliance: Not later than August 1, 1959
Technical illustration of an aircraft propeller assembly
Problem area Propeller

58-24-01

final rule

HAMILTON STANDARD Models 2H17K3, 2H17U3, 2H17AA3 and 2H17AC3 Propellers

Unsafe Condition: 2H17K3, 2H17U3, and 2H17AA3 blades have a substantial reduction in fatigue resistance after 5,000 operational hours. 2H17AC3 blades may require removal due to limited service data at 5,400 operatio...

Category: appliance Compliance: Compliance required as indicated.

56-22-01

final rule

HAMILTON STANDARD Applies to all Hamilton Standard Aluminum Alloy Propeller Blades

Unsafe Condition: Omission of EC776 cement as a prime coat under BB1007 in the cement sequence for adhering rubber accessories to Hamilton Standard aluminum blades has resulted in corrosion of the blade area under t...

Category: appliance Compliance: Compliance required for 6507 blades before July 1, 1957; all other blades before January 1, 1958.

56-19-02

final rule

HAMILTON STANDARD Model 2J17 Propellers

Unsafe Condition: Corrosion and defects in Hamilton Standard 2J17 propeller blades could lead to blade failure, and improper operation or maintenance could result in unsafe r.p.m. conditions or deicer system malfunc...

Category: appliance Compliance: Compliance required as specified herein.
Technical illustration of an aircraft propeller assembly
Problem area Propeller

57-13-05

final rule

HAMILTON STANDARD Applies to All Hamilton Standard Aluminum Alloy Blades Used in Hydromatic (Noncounterweight Type) Propellers

Unsafe Condition: Severe corrosion in the seal area at the shank of blades not incorporating a corrosion barrier, as evidenced by a failed blade that did not have the recommended corrosion barriers from Service Bull...

Category: appliance Compliance: At each removal of propeller blade from hub after December 1, 1957, and prior to September 1, 195...

58-22-01

final rule

HAMILTON STANDARD 6800, 6900, and 7000 Series Externally Surface-Treated Aluminum Alloy Blades (Airfoil Shotpeened and/or Shank Rolled, Including Nickel-Plated Blades)

Unsafe Condition: Two surface-treated aluminum alloy blades fractured during operation due to blade bending which may have a serious detrimental effect on the fatigue strength of a blade.

Category: appliance Compliance: At first blade overhaul after January 1, 1959, and at every overhaul thereafter.