AD 60-24-05
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Superior Aircraft Company | V | Airworthiness Directives; Superior (Culver) V and V2 Aircraft |
| aircraft | Superior Aircraft Company | V-2 | Airworthiness Directives; Superior (Culver) V and V2 Aircraft |
Unsafe Condition
Fuel cell failures due to icing or water accumulation in the fuel cell vent outlet
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Install a nonicing and nonwater accumulating fuel cell vent outlet (Superior P/N 12270 or equivalent) within the next 25 hours of operation. Inspect fuel cell attachments to wing structure during vent modification and at each 100-hour/periodic inspection; recement failed areas before next flight.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within the next 25 hours of operation, but not later than the next periodic or progressive inspection
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Superior (Culver) V and V2 aircraft, all serial numbers
AI-generated summary from the source AD text. Verify against the official source before acting.
Federal Register Abstract
Fuel Cells Vent Outlet
Applicability Source Text
Show captured applicability text from the source AD
AD Final Rules - DRS_60-24-05.html Copy URL Print/Save as PDF Document Versions Feedback Details AD Number: 60-24-05 Document Type: AD Final Rules Docket Number: Unknown Subject Heading: Airworthiness Directives; Superior (Culver) V and V2 Aircraft Subject: Fuel Cells Vent Outlet Status: Current Citation: This information is not available. Citation Publish Date: Effective Date: 12/13/1960 Make: Superior Aircraft Company Model: V | V-2 Product Type: Aircraft Product Subtype: Small Airplane Affected AD: Superseded AD: Affected By: Superseded By: Service/Office: Office of Primary Responsibility: CFR Part Reference: Part 39 Comments: AIRWORTHINESS DIRECTIVES FINAL RULES: 60-24-05 CITATION: This information is not available. PAGE NUMBER: DOCKET NUMBER: Unknown AMENDMENT: AD NUMBER: 60-24-05 SUBJECT HEADING: Airworthiness Directives; Superior (Culver) V and V2 Aircraft ACTION: SUMMARY: DATES: Effective December 13, 1960. ADDRESSES: FOR FURTHER INFORMATION CONTACT: SUPPLEMENTARY INFORMATION: REGULATORY TEXT: 60-24-05 SUPERIOR (Culver): Amdt. 223 Part 507 Federal Register November 15, 1960. Applies to All Superior (Culver) V and V2 Aircraft. Compliance required as indicated. To prevent fuel cell failures, the following must be accomplished: (a) Within the next 25 hours of operation, but not later than the next periodic or progressive inspection, install a nonicing and nonwater accumulating fuel cell vent outlet (Superior P/N 12270 or equivalent) that will provide positive pressure within the vapor spaces of the cells during normal flight conditions. (b) Inspect the attachment of the fuel cells to the wing structure at the time of the vent outlet modification and at each succeeding 100-hour inspection (if required by CAR 43.22) and each periodic aircraft inspection. Any attachment areas that are found to have failed must be recemented prior to the next flight. (Superior Aircraft Company Service Bulletin No. 25 covers this subject.) This directive effective December 13, 1960. FOOTER:
Document Text
Show stored source text (verify against official source)
AD Final Rules - DRS_60-24-05.html Copy URL Print/Save as PDF Document Versions Feedback Details AD Number: 60-24-05 Document Type: AD Final Rules Docket Number: Unknown Subject Heading: Airworthiness Directives; Superior (Culver) V and V2 Aircraft Subject: Fuel Cells Vent Outlet Status: Current Citation: This information is not available. Citation Publish Date: Effective Date: 12/13/1960 Make: Superior Aircraft Company Model: V | V-2 Product Type: Aircraft Product Subtype: Small Airplane Affected AD: Superseded AD: Affected By: Superseded By: Service/Office: Office of Primary Responsibility: CFR Part Reference: Part 39 Comments: AIRWORTHINESS DIRECTIVES FINAL RULES: 60-24-05 CITATION: This information is not available. PAGE NUMBER: DOCKET NUMBER: Unknown AMENDMENT: AD NUMBER: 60-24-05 SUBJECT HEADING: Airworthiness Directives; Superior (Culver) V and V2 Aircraft ACTION: SUMMARY: DATES: Effective December 13, 1960. ADDRESSES: FOR FURTHER INFORMATION CONTACT: SUPPLEMENTARY INFORMATION: REGULATORY TEXT: 60-24-05 SUPERIOR (Culver): Amdt. 223 Part 507 Federal Register November 15, 1960. Applies to All Superior (Culver) V and V2 Aircraft. Compliance required as indicated. To prevent fuel cell failures, the following must be accomplished: (a) Within the next 25 hours of operation, but not later than the next periodic or progressive inspection, install a nonicing and nonwater accumulating fuel cell vent outlet (Superior P/N 12270 or equivalent) that will provide positive pressure within the vapor spaces of the cells during normal flight conditions. (b) Inspect the attachment of the fuel cells to the wing structure at the time of the vent outlet modification and at each succeeding 100-hour inspection (if required by CAR 43.22) and each periodic aircraft inspection. Any attachment areas that are found to have failed must be recemented prior to the next flight. (Superior Aircraft Company Service Bulletin No. 25 covers this subject.) This directive effective December 13, 1960. FOOTER:
Source: Official FAA Source ↗
Retrieved: Apr 8, 2026
Rights: U.S. Government Public Domain
This site is not affiliated with or endorsed by the FAA. Always verify with official sources.