AD 60-24-05

final rule
Data completeness: 70%

Airworthiness Directives; Superior (Culver) V and V2 Aircraft

AD Number
60-24-05
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Unknown
FR Citation
This information is not available.

Applicability

TypeManufacturerModelDetails
aircraft Superior Aircraft Company V Airworthiness Directives; Superior (Culver) V and V2 Aircraft
aircraft Superior Aircraft Company V-2 Airworthiness Directives; Superior (Culver) V and V2 Aircraft

Unsafe Condition

Fuel cell failures due to icing or water accumulation in the fuel cell vent outlet

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Install a nonicing and nonwater accumulating fuel cell vent outlet (Superior P/N 12270 or equivalent) within the next 25 hours of operation. Inspect fuel cell attachments to wing structure during vent modification and at each 100-hour/periodic inspection; recement failed areas before next flight.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within the next 25 hours of operation, but not later than the next periodic or progressive inspection

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Superior (Culver) V and V2 aircraft, all serial numbers

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 8, 2026

Rights: U.S. Government Public Domain

This site is not affiliated with or endorsed by the FAA. Always verify with official sources.