AD 60-24-05
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Superior Aircraft Company | V | Airworthiness Directives; Superior (Culver) V and V2 Aircraft |
| aircraft | Superior Aircraft Company | V-2 | Airworthiness Directives; Superior (Culver) V and V2 Aircraft |
Unsafe Condition
Fuel cell failures due to icing or water accumulation in the fuel cell vent outlet
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Install a nonicing and nonwater accumulating fuel cell vent outlet (Superior P/N 12270 or equivalent) within the next 25 hours of operation. Inspect fuel cell attachments to wing structure during vent modification and at each 100-hour/periodic inspection; recement failed areas before next flight.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within the next 25 hours of operation, but not later than the next periodic or progressive inspection
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Superior (Culver) V and V2 aircraft, all serial numbers
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 8, 2026
Rights: U.S. Government Public Domain