Embraer - Empresa Brasileira de Aeronautica S.A. | Embraer S.A. ERJ 190-100 ECJ Airworthiness Directives

Browse ADs indexed for this model. Applicability depends on your aircraft configuration.

Check your aircraft configuration

2010-10-07

final rule

Airworthiness Directives; Empresa Brasileira de Aeronautica S.A. (EMBRAER) Model ERJ 170 and Model ERJ 190 Airplanes

Unsafe Condition: Occurrence of outboard slat skew sensor failure in open or closed position. The combination of an outboard slat skew sensor failed closed, an outboard slat actuator structural failure (rupture), an...

Effective: Jun 17, 2010 Category: aircraft Compliance: Within 50 flight hours after the effective date of the AD.
Technical illustration of an aircraft flight control surface and actuator
Problem area Flight controls

2010-08-02

final rule

Airworthiness Directives; Empresa Brasileira de Aeronautica S.A. (EMBRAER) Model ERJ 170 and ERJ 190 Airplanes

Unsafe Condition: Failure of the firewall hydraulic shutoff valve, which, in combination with an engine fire, could result in the spread of an engine fire beyond the firewall.

Effective: May 19, 2010 Category: aircraft Compliance: Within the specified intervals as outlined in the AD, with optional replacement actions available.
Technical illustration of an aircraft turbine engine assembly
Problem area Engine

2009-06-16

final rule

Airworthiness Directives; Empresa Brasileira de Aeronautica S.A. (EMBRAER) Model ERJ 170 Airplanes and Model ERJ 190 Airplanes

Unsafe Condition: Failed bearings of the RAT generator may lead to RAT generator failure, which could result in reduced controllability of the airplane during in-flight emergencies.

Effective: Apr 30, 2009 Category: aircraft Compliance: Within 1,300 flight hours or 6 months after the effective date of this AD, whichever occurs first.
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system

2008-23-17

final rule

Airworthiness Directives; Empresa Brasileira de Aeronautica S.A. (EMBRAER) Model ERJ 170 and ERJ 190 Airplanes

Unsafe Condition: Escape slide system installation with tie-down straps used for escape slide packing not removed, preventing the aircraft door from reaching the fully open position and deployment of the escape slid...

Effective: Dec 30, 2008 Category: aircraft Compliance: Within 600 flight hours after the effective date of this AD

2008-18-01

final rule

Airworthiness Directives; Empresa Brasileira de Aeronautica S.A. (EMBRAER) Model ERJ 170 and ERJ 190 Airplanes

Unsafe Condition: The pressure equalization valve was not installed in the left-hand bulkhead blowout panel, on the forward and/or aft cargo compartments, thus affecting the effectiveness of fire detection, containm...

Effective: Oct 14, 2008 Category: aircraft Compliance: Within 500 flight hours for inspection, and within 700 flight hours for installation if necessary.
Technical illustration of a riveted aircraft structural panel and frame
Problem area Airframe structure