AD 2010-08-02

final rule
Data completeness: 70%

Airworthiness Directives; Empresa Brasileira de Aeronautica S.A. (EMBRAER) Model ERJ 170 and ERJ 190 Airplanes

AD Number
2010-08-02
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. FAA-2007-28377
FR Citation
75 FR 19193

Applicability

TypeManufacturerModelDetails
aircraft Embraer Various Airworthiness Directives; Empresa Brasileira de Aeronautica S.A. (EMBRAER) Model ERJ 170 and ERJ 190 Airplanes
aircraft Aviat Various Airworthiness Directives; Empresa Brasileira de Aeronautica S.A. (EMBRAER) Model ERJ 170 and ERJ 190 Airplanes

Unsafe Condition

Failure of the firewall hydraulic shutoff valve, which, in combination with an engine fire, could result in the spread of an engine fire beyond the firewall.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Conduct repetitive operational checks of the firewall hydraulic shutoff valve. Replace the valve if necessary. Optional terminating action: Replace an affected valve with a new valve, P/N 975287-7, as an alternative to the 600-flight-hour-interval inspections.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within the specified intervals as outlined in the AD, with optional replacement actions available.

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Empresa Brasileira de Aeronautica S.A. (EMBRAER) Model ERJ 170 and ERJ 190 airplanes, including the Model ERJ 190-100 ECJ airplane.

AI-generated summary from the source AD text. Verify against the official source before acting.