Airbus SAS A320-111 Airworthiness Directives

Browse ADs indexed for this model. Applicability depends on your aircraft configuration.

Check your aircraft configuration

2005-22-10

final rule

Airworthiness Directives; Airbus Model A320-111 Airplanes, and Model A320-200 Series Airplanes

Unsafe Condition: Mis-rigged elevator servo-controls due to improperly installed tail cone triangles during production, which could result in low hinge moments and possible vibrations if combined with elevator freep...

Effective: Dec 5, 2005 Category: aircraft Compliance: Within 800 flight hours after the effective date of this AD.
Technical illustration of an aircraft flight control surface and actuator
Problem area Flight controls

2005-22-05

final rule

Airworthiness Directives; Airbus Model A320-111, -211, -212, and -231 Airplanes

Unsafe Condition: Chafing of the fuel pump cables, which could result in electrical arcing and possible ignition of fuel vapors and consequent explosion of the fuel tank.

Effective: Nov 30, 2005 Category: aircraft Compliance: Within 58 months after the effective date of this AD.
Technical illustration of an aircraft fuel pump, filter, valve, and lines
Problem area Fuel system

2005-20-17

final rule

Airworthiness Directives; Airbus Model A319-100 Series Airplanes; Model A320-111 Series Airplanes; Model A320-200 Series Airplanes; and Model A321-100 and -200 Series Airplanes

Unsafe Condition: Failure of the parking brake while the airplane was on the holding point of the runway before takeoff, leading to a runway departure.

Effective: Nov 9, 2005 Category: aircraft Compliance: Within 52 months after the effective date of this AD.
Technical illustration of an aircraft landing gear and wheel assembly
Problem area Landing gear

2005-07-14

final rule

Airworthiness Directives; Airbus Model A318, A319, A320, and A321 Series Airplanes

Unsafe Condition: A broken piston rod bearing of the spoiler servo control could cause loss of the associated hydraulic system and spoiler extension, potentially resulting in reduced controllability of the airplane.

Effective: May 12, 2005 Category: aircraft Compliance: Before further flight

2005-06-06

final rule

Airworthiness Directives; Airbus Model A319, A320, and A321 Series Airplanes

Unsafe Condition: Oil vapor leakage from the APU AC generator, which, when combined with an electric arc at the electrical receptacle, could result in a fire or explosion in the APU compartment during flight.

Effective: Apr 22, 2005 Category: aircraft Compliance: Within 20 months after the effective date of this AD.
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system

2004-14-23

final rule

Airworthiness Directives; Airbus Model A319-111, -112, -113, and -114; A320-111, -211, -212, and -214; and A321-111, -112, and -211 Series Airplanes

Unsafe Condition: Inadvertent deployment of the thrust reverser door, which could result in reduced controllability of the airplane.

Effective: Aug 23, 2004 Category: aircraft Compliance: Before the actuator accumulates 7,000 total flight cycles since its last overhaul, or within 500 ...

2004-12-19

final rule

Airworthiness Directives; Airbus Model A319, A320, and A321 Series Airplanes

Unsafe Condition: Ignition of the input filter capacitors of the transformer rectifier unit (TRU) in position 2 of the avionics compartment, which could potentially result in smoke in the cockpit.

Effective: Jul 27, 2004 Category: aircraft Compliance: Within 15,000 total flight hours or within 16 months after the effective date of this AD, whichev...

2004-06-02

final rule

Airworthiness Directives; Airbus Model A319, A320, and A321 Series Airplanes

Unsafe Condition: Failure of a lower guide rod fitting could cause a rear passenger door to jam during opening, delaying an emergency evacuation and resulting in injury to passengers or crew members.

Effective: Apr 22, 2004 Category: aircraft Compliance: Before further flight.

2004-05-04

final rule

Airworthiness Directives; Airbus Model A319 and A320 Series Airplanes

Unsafe Condition: Insufficient clearance between FQI probes and adjacent structure, and incorrect support bracket position or part number, could lead to electrical arcing in the event of lightning strikes, creating ...

Effective: Apr 9, 2004 Category: aircraft Compliance: Before further flight
Technical illustration of an aircraft fuel pump, filter, valve, and lines
Problem area Fuel system

2002-06-53

final rule

Airworthiness Directives; Airbus Model A319, A320, A321, A330, and A340 Series Airplanes Equipped With Certain Thales Avionics Digital Distance and Radio Magnetic Indicators (DDRMIs)

Unsafe Condition: Failure of the Thales Avionics Digital Distance and Radio Magnetic Indicators (DDRMIs) could cause loss of data from affected computers to other systems, leading to degradation or total failure of ...

Effective: Apr 29, 2002 Category: aircraft Compliance: Before further flight.

2001-26-20

final rule

Airworthiness Directives; Airbus Model A319, A320, and A321 Series Airplanes

Unsafe Condition: Missing lock pin in the forward and aft lower bogies of the left- and right-hand sliding windows of the flightcrew compartment could cause the window to jam in the closed position, preventing fligh...

Effective: Feb 8, 2002 Category: aircraft Compliance: Within 50 flight hours after the effective date of the AD.

2001-26-21

final rule

Airworthiness Directives; Airbus Model A319, A320, and A321 Series Airplanes

Unsafe Condition: Faulty operation of the low-pressure solenoid valve for the crew oxygen supply could prevent oxygen from being supplied to the airplane crew when needed, such as in the event of smoke in the cabin ...

Effective: Feb 8, 2002 Category: aircraft Compliance: Before further flight.

2001-15-16

final rule

Airworthiness Directives; Airbus Model A319, A320, and A321 Series Airplanes

Unsafe Condition: Blockage of the outer door handle flap in an intermediate pushed-in position, which may prevent a passenger door from opening from the inside of the airplane, thereby delaying an emergency evacuation.

Effective: Sep 4, 2001 Category: aircraft Compliance: Within 500 flight hours after the effective date of this AD.

2001-15-06

final rule

Airworthiness Directives; Airbus Model A319, A320, and A321 Series Airplanes

Unsafe Condition: Ingestion of sill support-log material into the aspirator of the escape slide, which could result in failure of the escape slide to inflate.

Effective: Aug 27, 2001 Category: aircraft Compliance: Within 9 months after the effective date of August 27, 2001.

2000-12-04 Recurring

final rule

Airworthiness Directives; Airbus Model A319, A320, and A321 Series Airplanes

Unsafe Condition: Fatigue cracking of fuselage frames and frame feet at fuselage frames FR37 through FR41, adjacent to stringer 23, which could lead to reduced structural integrity of the fuselage.

Effective: Jul 19, 2000 Category: aircraft Compliance: Varies by configuration: within 3,500 flight cycles after the effective date, or within 16,000 fl...
Technical illustration of a riveted aircraft structural panel and frame
Problem area Airframe structure

99-02-10

final rule

Airworthiness Directives; Airbus Model A320 Series Airplanes

Unsafe Condition: Leakage from hydraulic pipe fittings in the trimmable horizontal stabilizer (THS) could result in failure of the THS and consequent reduced controllability of the airplane.

Effective: Feb 23, 1999 Category: aircraft Compliance: Within 500 flight hours after the effective date of this AD for the inspection; within 3,500 flig...

98-20-30

final rule

Airworthiness Directives; Airbus Model A320 Series Airplanes Equipped with a Bulk Cargo Door

Unsafe Condition: Fatigue cracking of the upper frame flanges could result in reduced structural integrity of the airplane.

Effective: Oct 30, 1998 Category: aircraft Compliance: Prior to the accumulation of 20,000 total flight cycles, or within 1,200 flight cycles after the ...

98-19-07

final rule

Airworthiness Directives; Airbus Model A320-111, -211, and -231 Series Airplanes

Unsafe Condition: Fatigue cracking of certain fastener holes on the outer frames of the fuselage, which could result in reduced structural integrity of the airplane.

Effective: Oct 15, 1998 Category: aircraft Compliance: Prior to the accumulation of 20,000 total flight cycles, or within 4,000 flight cycles after the ...

98-18-16

final rule

Airworthiness Directives; Airbus Model A320 Series Airplanes

Unsafe Condition: Structural damage to the tail section when it strikes the runway, which could result in depressurization of the fuselage during flight.

Effective: Oct 8, 1998 Category: aircraft Compliance: Within 6 years after May 15, 1997 (for paragraph (a)), and within 5 years after October 8, 1998 (...

98-15-04

final rule

Airworthiness Directives; Airbus Model A320 Series Airplanes

Unsafe Condition: Fatigue cracking of the bottom flanges of the longitudinal floor beams at frame 43 and fatigue cracking of the fastener holes in the longitudinal floor beams, which could result in reduced structur...

Effective: Aug 19, 1998 Category: aircraft Compliance: Prior to the accumulation of 20,000 total flight cycles, or within 1,000 flight cycles after the ...

98-12-05

final rule

Airworthiness Directives; Airbus Model A320-111 Series Airplanes

Unsafe Condition: Cracking around the attachment holes for the access panels in the lower skin of the wing between ribs 13 and 22 could result in reduced structural integrity of the airplane.

Effective: Jun 18, 1998 Category: aircraft Compliance: Prior to the accumulation of 20,000 total flight cycles, or within 60 days after the effective da...

98-09-18

final rule

Airworthiness Directives; Airbus Industrie Model A320 and A321 Series Airplanes

Unsafe Condition: Adverse airplane-pilot coupling characteristics could lead to reduced controllability due to uncommanded movements of the ailerons and pilot response.

Effective: Jun 3, 1998 Category: aircraft Compliance: Within 1 year after the effective date of this AD
Technical illustration of an aircraft flight control surface and actuator
Problem area Flight controls

98-04-11

final rule

Airworthiness Directives; Airbus Model A320 and A321 Series Airplanes

Unsafe Condition: Possible delays in deceleration when landing with strong cross winds and/or on a contaminated runway, which could increase the potential for landing overrun.

Effective: Mar 24, 1998 Category: aircraft Compliance: Within 12 months after the effective date of this AD

98-01-17

final rule

Airworthiness Directives; Airbus Model A320 Series Airplanes

Unsafe Condition: Failure of the main landing gear (MLG) to retract properly as a result of failure of a capacitor in the MLG circuitry and subsequent electrical power interruption.

Effective: Feb 17, 1998 Category: aircraft Compliance: Within 8 months after the effective date of this AD
Technical illustration of an aircraft landing gear and wheel assembly
Problem area Landing gear

97-09-04

final rule

Airworthiness Directives; Airbus Industrie Model A320, A321, A330, and A340 Series Airplanes Equipped with Westland-Sitec Fire Shutoff Valves Having Part Number EO3000

Unsafe Condition: Fire shutoff valves (FSOV) are not closing completely during maintenance testing, which would fuel the fire and lead to the loss of fluid in associated hydraulic systems, causing those systems to f...

Effective: May 29, 1997 Category: aircraft Compliance: Within 6 months after the effective date (May 29, 1997), and thereafter at intervals not to excee...