Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Airbus | A319 | Airworthiness Directives; Airbus Model A319, A320, and A321 Series Airplanes |
Unsafe Condition
Oil vapor leakage from the APU AC generator, which, when combined with an electric arc at the electrical receptacle, could result in a fire or explosion in the APU compartment during flight.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Within 20 months after the effective date of this AD, modify the APU AC generator by doing all the actions in accordance with the Accomplishment Instructions of Airbus Service Bulletin A320-24-1106, Revision 01, dated May 13, 2004.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 20 months after the effective date of this AD.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Airbus Model A319, A320, and A321 series airplanes; certificated in any category; equipped with any Hamilton Sundstrand Auxiliary Power Unit (APU) alternating current (AC) generator having part number 5906732, 5909006, or 5910047; with up to amendment 17 included; on which Airbus Modification 32614 has not been done.
AI-generated summary from the source AD text. Verify against the official source before acting.