AD 94-01-14
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Bombardier Inc. | CL-600-2B19 (Regional Jet Series 100) | Airworthiness Directives; CANADAIR LIMITED Model CL-600-2B19 (Regional Jet) Series Airplanes |
Unsafe Condition
The retaining ring can become unseated from its positional groove on the input shaft of the integrated drive generator (IDG) constant speed drive (CSD), resulting in loss of IDG oil and subsequent disconnection of the IDG, and causing abnormal movement of the input shaft which could damage the engine seal and lead to loss of engine oil and engine shutdown during flight.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Add AFM limitations requiring both IDGs operational for dispatch; inspect IDG oil levels within 14 days and every 30 hours time-in-service, replenishing oil as needed; replace or modify IDGs if oil level is on or below 'ADD' mark or if disconnected during flight; optionally modify IDGs per service bulletin to terminate inspections and AFM revision.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 14 days after the effective date of this AD, or prior to further flight as specified.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Bombardier Inc. Model CL-600-2B19 (Regional Jet Series 100), serial numbers 7003 through 7028 inclusive.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 8, 2026
Rights: U.S. Government Public Domain