AD 93-06-02
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Piper Aircraft Inc. | PA-23 | Airworthiness Directives; PIPER AIRCRAFT CORPORATION Models PA-23-150, PA-23-160, PA-23-235, and PA-23-250 airplanes |
| aircraft | Piper Aircraft Inc. | PA-23-160 | Airworthiness Directives; PIPER AIRCRAFT CORPORATION Models PA-23-150, PA-23-160, PA-23-235, and PA-23-250 airplanes |
| aircraft | Piper Aircraft Inc. | PA-23-235 | Airworthiness Directives; PIPER AIRCRAFT CORPORATION Models PA-23-150, PA-23-160, PA-23-235, and PA-23-250 airplanes |
| aircraft | Piper Aircraft Inc. | PA-23-250 | Airworthiness Directives; PIPER AIRCRAFT CORPORATION Models PA-23-150, PA-23-160, PA-23-235, and PA-23-250 airplanes |
| aircraft | Piper Aircraft Inc. | PA-23-250 (Navy UO-1) | Airworthiness Directives; PIPER AIRCRAFT CORPORATION Models PA-23-150, PA-23-160, PA-23-235, and PA-23-250 airplanes |
Unsafe Condition
Fuel leakage and possible fire due to Parker 'Push-Lok' flexible fuel hose (MCA P/N 11059-4 or Parker-Hannifin P/N 801-6/250PSI) installation in Met-Co-Aire 48-gallon fuel tip tanks.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Replace Parker 'Push-Lok' fuel hose with Stratoflex hose (MCA P/N 11059-10 or Parker-Hannifin P/N 130001-6S-0154) per Met-Co-Aire Service Bulletin 23-001. Use special flight permits under FAR 21.197/21.199 to reach a maintenance location. Alternative methods may be approved by FAA.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
within the next 100 hours time-in-service after the effective date of this AD
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Piper Aircraft Corporation Models PA-23-150, PA-23-160, PA-23-235, PA-23-250 (all serial numbers) with Met-Co-Aire 48-gallon fuel tip tanks per STC SA1480WE
AI-generated summary from the source AD text. Verify against the official source before acting.
Federal Register Abstract
Fuel Hose
Applicability Source Text
Show captured applicability text from the source AD
AD Final Rules - DRS_93-06-02.html Copy URL Print/Save as PDF Document Versions Feedback Details AD Number: 93-06-02 Document Type: AD Final Rules Docket Number: 92-CE-48-AD Subject Heading: Airworthiness Directives; PIPER AIRCRAFT CORPORATION Models PA-23-150, PA-23-160, PA-23-235, and PA-...Show more Subject: Fuel Hose Status: Current Citation: This information is not available. Citation Publish Date: 03/25/1993 Effective Date: 05/12/1993 Make: Piper Aircraft Inc. Model: PA-23 | PA-23-160 | PA-23-235 | PA-23-250 | PA-23-250 (Navy UO-1) Product Type: Aircraft Product Subtype: Small Airplane Affected AD: Superseded AD: Affected By: Superseded By: Service/Office: AIR-700: Compliance & Airworthiness Division Office of Primary Responsibility: AIR-720: Operational Safety Branch CFR Part Reference: Part 39 Comments: AIRWORTHINESS DIRECTIVES FINAL RULES: 93-06-02 CITATION: This information is not available. PAGE NUMBER: DOCKET NUMBER: 92-CE-48-AD AMENDMENT: 39-8527 AD NUMBER: 93-06-02 SUBJECT HEADING: Airworthiness Directives; PIPER AIRCRAFT CORPORATION Models PA-23-150, PA-23-160, PA-23-235, and PA-23-250 airplanes ACTION: SUMMARY: DATES: Effective May 12, 1993. ADDRESSES: FOR FURTHER INFORMATION CONTACT: SUPPLEMENTARY INFORMATION: REGULATORY TEXT: 93-06-02 PIPER AIRCRAFT CORPORATION: Amendment 39-8527. Docket No. 92- CE-48-AD. Applicability: Models PA-23-150, PA-23-160, PA-23-235, and PA-23-250 airplanes (all serial numbers) that have Met-Co-Aire 48-gallon fuel tip tanks installed in accordance with Supplemental Type Certificate SA1480WE, certificated in any category. Compliance: Required within the next 100 hours time-in-service after the effective date of this AD, unless already accomplished. NOTE 1: The compliance time referenced in this AD takes precedence over that referenced in Met-Co-Aire (MCA) Service Bulletin No. 23-001, dated July 1992. To prevent fuel leakage and possible fire, which could result in passenger injury, accomplish the following: (a) Replace any existing Parker "Push-Lok" flexible fuel hose, MCA part number (P/N) 11059-4 or Parker-Hannifin P/N 801-6/250PSI, with a Stratoflex hose, MCA P/N 11059-10 or Parker-Hannifin P/N 130001-6S-0154, in accordance with the instructions in Met-Co-Aire Service Bulletin No. 23-001, dated July 1992. (b) Special flight permits may be issued in accordance with FAR 21.197 and 21.199 to operate the airplane to a location where the requirements of this AD can be accomplished. (c) An alternative method of compliance or adjustment of the compliance time that provides an equivalent level of safety may be approved by the Manager, Los Angeles Aircraft Certification Office, FAA, 3229 E. Spring Street, Long Beach, California 90806-2425. The request shall be forwarded through an appropriate FAA Maintenance Inspector, who may add comments and then send it to the Manager, Los Angeles Aircraft Certification Office. NOTE 2: Information concerning the existence of approved alternative methods of compliance with this AD, if any, may be obtained from the Los Angeles Aircraft Certification Office. (d) The replacement required by this AD shall be done in accordance with Met-Co-Aire Service Bulletin No. 23-001, dated July 1992. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR Part 51. Copies may be obtained from Met-Co-Aire, P.O. Box 2216, Fullerton, California 92633. Copies may be inspected at the FAA, Central Region, Office of the Assistant Chief Counsel, Room 1558, 601 E. 12th Street, Kansas City, Missouri, or at the Office of the Federal Register, 800 North Capitol Street, NW., suite 700, Washington, DC. (f) This amendment becomes effective on May 12, 1993. FOOTER:
Document Text
Show stored source text (verify against official source)
AD Final Rules - DRS_93-06-02.html Copy URL Print/Save as PDF Document Versions Feedback Details AD Number: 93-06-02 Document Type: AD Final Rules Docket Number: 92-CE-48-AD Subject Heading: Airworthiness Directives; PIPER AIRCRAFT CORPORATION Models PA-23-150, PA-23-160, PA-23-235, and PA-...Show more Subject: Fuel Hose Status: Current Citation: This information is not available. Citation Publish Date: 03/25/1993 Effective Date: 05/12/1993 Make: Piper Aircraft Inc. Model: PA-23 | PA-23-160 | PA-23-235 | PA-23-250 | PA-23-250 (Navy UO-1) Product Type: Aircraft Product Subtype: Small Airplane Affected AD: Superseded AD: Affected By: Superseded By: Service/Office: AIR-700: Compliance & Airworthiness Division Office of Primary Responsibility: AIR-720: Operational Safety Branch CFR Part Reference: Part 39 Comments: AIRWORTHINESS DIRECTIVES FINAL RULES: 93-06-02 CITATION: This information is not available. PAGE NUMBER: DOCKET NUMBER: 92-CE-48-AD AMENDMENT: 39-8527 AD NUMBER: 93-06-02 SUBJECT HEADING: Airworthiness Directives; PIPER AIRCRAFT CORPORATION Models PA-23-150, PA-23-160, PA-23-235, and PA-23-250 airplanes ACTION: SUMMARY: DATES: Effective May 12, 1993. ADDRESSES: FOR FURTHER INFORMATION CONTACT: SUPPLEMENTARY INFORMATION: REGULATORY TEXT: 93-06-02 PIPER AIRCRAFT CORPORATION: Amendment 39-8527. Docket No. 92- CE-48-AD. Applicability: Models PA-23-150, PA-23-160, PA-23-235, and PA-23-250 airplanes (all serial numbers) that have Met-Co-Aire 48-gallon fuel tip tanks installed in accordance with Supplemental Type Certificate SA1480WE, certificated in any category. Compliance: Required within the next 100 hours time-in-service after the effective date of this AD, unless already accomplished. NOTE 1: The compliance time referenced in this AD takes precedence over that referenced in Met-Co-Aire (MCA) Service Bulletin No. 23-001, dated July 1992. To prevent fuel leakage and possible fire, which could result in passenger injury, accomplish the following: (a) Replace any existing Parker "Push-Lok" flexible fuel hose, MCA part number (P/N) 11059-4 or Parker-Hannifin P/N 801-6/250PSI, with a Stratoflex hose, MCA P/N 11059-10 or Parker-Hannifin P/N 130001-6S-0154, in accordance with the instructions in Met-Co-Aire Service Bulletin No. 23-001, dated July 1992. (b) Special flight permits may be issued in accordance with FAR 21.197 and 21.199 to operate the airplane to a location where the requirements of this AD can be accomplished. (c) An alternative method of compliance or adjustment of the compliance time that provides an equivalent level of safety may be approved by the Manager, Los Angeles Aircraft Certification Office, FAA, 3229 E. Spring Street, Long Beach, California 90806-2425. The request shall be forwarded through an appropriate FAA Maintenance Inspector, who may add comments and then send it to the Manager, Los Angeles Aircraft Certification Office. NOTE 2: Information concerning the existence of approved alternative methods of compliance with this AD, if any, may be obtained from the Los Angeles Aircraft Certification Office. (d) The replacement required by this AD shall be done in accordance with Met-Co-Aire Service Bulletin No. 23-001, dated July 1992. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR Part 51. Copies may be obtained from Met-Co-Aire, P.O. Box 2216, Fullerton, California 92633. Copies may be inspected at the FAA, Central Region, Office of the Assistant Chief Counsel, Room 1558, 601 E. 12th Street, Kansas City, Missouri, or at the Office of the Federal Register, 800 North Capitol Street, NW., suite 700, Washington, DC. (f) This amendment becomes effective on May 12, 1993. FOOTER:
Source: Official FAA Source ↗
Retrieved: Apr 8, 2026
Rights: U.S. Government Public Domain