AD 80-26-07 R1

final rule

Airworthiness Directives; GROUPEMENT d'INTERET ECONOMIQUE AIRBUS (AIRBUS INDUSTRIE): Model A300 Series Airplanes

AD Number
80-26-07 R1
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Unknown
FR Citation
This information is not available.
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system

Applicability

TypeManufacturerModelDetails
aircraft Airbus A300 B2-1A Airworthiness Directives; GROUPEMENT d'INTERET ECONOMIQUE AIRBUS (AIRBUS INDUSTRIE): Model A300 Series Airplanes
aircraft Airbus A300 B2-1C Airworthiness Directives; GROUPEMENT d'INTERET ECONOMIQUE AIRBUS (AIRBUS INDUSTRIE): Model A300 Series Airplanes
aircraft Airbus A300 B2-203 Airworthiness Directives; GROUPEMENT d'INTERET ECONOMIQUE AIRBUS (AIRBUS INDUSTRIE): Model A300 Series Airplanes
aircraft Airbus A300 B2K-3C Airworthiness Directives; GROUPEMENT d'INTERET ECONOMIQUE AIRBUS (AIRBUS INDUSTRIE): Model A300 Series Airplanes
aircraft Airbus A300 B4-103 Airworthiness Directives; GROUPEMENT d'INTERET ECONOMIQUE AIRBUS (AIRBUS INDUSTRIE): Model A300 Series Airplanes
aircraft Airbus A300 B4-203 Airworthiness Directives; GROUPEMENT d'INTERET ECONOMIQUE AIRBUS (AIRBUS INDUSTRIE): Model A300 Series Airplanes
aircraft Airbus A300 B4-2C Airworthiness Directives; GROUPEMENT d'INTERET ECONOMIQUE AIRBUS (AIRBUS INDUSTRIE): Model A300 Series Airplanes

Unsafe Condition

Improper installation of the APU generator feeder cable splices could lead to a possible fire hazard.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Within one week after the effective date, render the APU generator electrically inoperative and place an 'APU GENERATOR INOP' placard for specified serial numbers. Inspect feeder cable splices within 100 flights and replace incorrect splices or sleeves by July 1, 1981. Additional inspections within 250 flights and replacements by December 31, 1981, as required.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within one week after the effective date of this AD; within the next 100 flights; by July 1, 1981; within the next 250 flights; by December 31, 1981.

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Airbus Model A300 B2-1A, B2-1C, B2-203, B2K-3C, B4-103, B4-203, B4-2C series airplanes, manufacturer serial numbers (MSN) 002 through 119 except specific excluded serial numbers.

AI-generated summary from the source AD text. Verify against the official source before acting.

Federal Register Abstract

Placard - APU Generator

Applicability Source Text

Show captured applicability text from the source AD
AD Final Rules - DRS_80-26-07_R.html
Copy URL
Print/Save as PDF
Document Versions
 Feedback
Details
AD Number:
80-26-07 R1
Document Type:
AD Final Rules
Docket Number:
Unknown
Subject Heading:
Airworthiness Directives; GROUPEMENT d'INTERET ECONOMIQUE AIRBUS (AIRBUS INDUSTRIE): Model A300 Se...Show more
Subject:
Placard - APU Generator
Status:
Current
Citation:
This information is not available.
Citation Publish Date:
Effective Date:
07/22/1981
Make:
Airbus
Model:
A300 B2-1A | A300 B2-1C | A300 B2-203 | A300 B2K-3C | A300 B4-103 | A300 B4-203 | A300 B4-2C
Product Type:
Aircraft
Product Subtype:
Large Airplane
Affected AD:
Superseded AD:
Affected By:
Superseded By:
Service/Office:
Office of Primary Responsibility:
CFR Part Reference:
Part 39
Comments:
AIRWORTHINESS DIRECTIVES FINAL RULES: 80-26-07 R1
CITATION:   This information is not available.

PAGE NUMBER:  

DOCKET NUMBER:   Unknown

AMENDMENT:   39-4162

AD NUMBER:   80-26-07 R1

SUBJECT HEADING:   Airworthiness Directives; GROUPEMENT d'INTERET ECONOMIQUE AIRBUS (AIRBUS INDUSTRIE): Model A300
Series Airplanes

ACTION:  

SUMMARY:  

DATES:   Effective July 22, 1981.

ADDRESSES:  

FOR FURTHER INFORMATION CONTACT:  

SUPPLEMENTARY INFORMATION:  

REGULATORY TEXT:  
80-26-07 R1 GROUPEMENT d'INTERET ECONOMIQUE AIRBUS (AIRBUS INDUSTRIE): Amendment 39-3996 as amended by Amendment 39-4162. Applies to Model A300 series airplanes certified in all categories.

Compliance required as indicated unless already accomplished.

To detect improper installation of the APU generator feeder cable splices and to prevent a possible fire hazard, accomplish the following:

A. Within one week after the effective date of this AD render the APU generator electrically inoperative and place an "APU GENERATOR INOP" placard in view of the flight crew in airplanes manufacturer serial numbers (MSN) 002 through 116 except 082, 089, 090, and 095, that have been modified in accordance with Airbus Industrie Modification No. 2676, until Paragraph E below is accomplished.

B. Within the next 100 flights after the effective date of this AD, inspect the APU generator feeder cable splices at station 809VS of manufacturer serial numbers (MSN) 002 through 116 except 082, 089, 090, and 095, which have not been modified by Airbus Industrie Modification No. 2676, in accordance with paragraphs DD.2 and .3 of Airbus Industrie ALL OPERATORS TELEX (AOT) 24/80/102 dated October 30, 1980, or paragraph 2.B(1)(A) of Airbus Industrie Service Bulletin Number A300-24-048 dated January 6, 1981, or later FAA approved revisions.

1. If any indication of splice overheat is found or any crimped splices are not correct, replace all affected feeder cable splices in accordance with Paragraph E, below, prior to the next flight or render the APU generator electrically inoperative and place an "APU GENERATOR INOP" placard in view of the flight crew until Paragraph E, below, is accomplished.

2. If incorrect insulating heat shrink sleeves are discovered, but no indications of splice overheat or incorrectly crimped splices are found, flight operations may be continued with inspections every 100 flights, until the replacement required by Paragraph C, below, is accomplished.

C. Replace all APU generator feeder crimped splices which have incorrect insulating heat shrink sleeves in accordance with Paragraph E, below, by July 1, 1981.

D. Replace all APU generator feeder crimped splices covered by B(1), above, in accordance with Paragraph E, below, by July 1, 1981.

E. Replace the splices and sleeves in accordance with Airbus Industrie AOT 24/80/102 dated October 30, 1980, or A300 Service Bulletin 24-048 dated January 6, 1981, or later FAA approved revisions.

F. Within the next 250 flights from the effective date of this amendment, unless already accomplished, inspect the APU generator feeder cable splices at stations 808VS and 160VS of manufacturer serial numbers (MSN) 002 through 119, except 029, 090, 112, and 117, in accordance with paragraph 2.b of Airbus Industrie Service Bulletin A300-24-050, dated March 31, 1981, or later FAA approved revisions.

1. If any indication of splice overheat is found, replace the defective splice(s) plus the corresponding splices of the same phase in accordance with paragraph G, prior to the next flight, or render the APU generator electrically inoperative and place an "APU GENERATOR INOP" placard in view of the flight crew until paragraph G below is accomplished.

2. If incorrectly crimped splices are found, replace the defective splices before December 31, 1981, in accordance with paragraph G below.

3. If no indications of overheating or incorrect crimping are found, no further action is required.

G. Replace the defective splices at stations 808VS and 160VS in accordance with Airbus Industrie Service Bulletin A300-24-049, dated March 31, 1981, or later FAA approved revisions.

H. Alternative methods of compliance with this AD which provide an equivalent level of safety may be utilized when they are approved by the Chief, Seattle Area Aircraft Certification Office, FAA Northwest Region.

The manufacturer's specifications and procedures identified and described in this directive are incorporated herein and made a part hereof pursuant to 5 U.S.C. 552(a)(1). All persons affected by this directive who have not already received these documents from the manufacturer may obtain copies upon request to Groupement d'Interet Economique, Airbus Industrie, Avenue Lucien, Servanty - B.P. No 33, 31700 Blagnac, France. These documents may also be examined at the FAA Northwest Region, 9010 East Marginal Way South, Seattle, Washington 98108.

Amendment 39-3996 became effective on December 30, 1980.

This amendment 39-4162 becomes effective July 22, 1981.

FOOTER:

Document Text

Show stored source text (verify against official source)
AD Final Rules - DRS_80-26-07_R.html
Copy URL
Print/Save as PDF
Document Versions
 Feedback
Details
AD Number:
80-26-07 R1
Document Type:
AD Final Rules
Docket Number:
Unknown
Subject Heading:
Airworthiness Directives; GROUPEMENT d'INTERET ECONOMIQUE AIRBUS (AIRBUS INDUSTRIE): Model A300 Se...Show more
Subject:
Placard - APU Generator
Status:
Current
Citation:
This information is not available.
Citation Publish Date:
Effective Date:
07/22/1981
Make:
Airbus
Model:
A300 B2-1A | A300 B2-1C | A300 B2-203 | A300 B2K-3C | A300 B4-103 | A300 B4-203 | A300 B4-2C
Product Type:
Aircraft
Product Subtype:
Large Airplane
Affected AD:
Superseded AD:
Affected By:
Superseded By:
Service/Office:
Office of Primary Responsibility:
CFR Part Reference:
Part 39
Comments:
AIRWORTHINESS DIRECTIVES FINAL RULES: 80-26-07 R1
CITATION:   This information is not available.

PAGE NUMBER:  

DOCKET NUMBER:   Unknown

AMENDMENT:   39-4162

AD NUMBER:   80-26-07 R1

SUBJECT HEADING:   Airworthiness Directives; GROUPEMENT d'INTERET ECONOMIQUE AIRBUS (AIRBUS INDUSTRIE): Model A300
Series Airplanes

ACTION:  

SUMMARY:  

DATES:   Effective July 22, 1981.

ADDRESSES:  

FOR FURTHER INFORMATION CONTACT:  

SUPPLEMENTARY INFORMATION:  

REGULATORY TEXT:  
80-26-07 R1 GROUPEMENT d'INTERET ECONOMIQUE AIRBUS (AIRBUS INDUSTRIE): Amendment 39-3996 as amended by Amendment 39-4162. Applies to Model A300 series airplanes certified in all categories.

Compliance required as indicated unless already accomplished.

To detect improper installation of the APU generator feeder cable splices and to prevent a possible fire hazard, accomplish the following:

A. Within one week after the effective date of this AD render the APU generator electrically inoperative and place an "APU GENERATOR INOP" placard in view of the flight crew in airplanes manufacturer serial numbers (MSN) 002 through 116 except 082, 089, 090, and 095, that have been modified in accordance with Airbus Industrie Modification No. 2676, until Paragraph E below is accomplished.

B. Within the next 100 flights after the effective date of this AD, inspect the APU generator feeder cable splices at station 809VS of manufacturer serial numbers (MSN) 002 through 116 except 082, 089, 090, and 095, which have not been modified by Airbus Industrie Modification No. 2676, in accordance with paragraphs DD.2 and .3 of Airbus Industrie ALL OPERATORS TELEX (AOT) 24/80/102 dated October 30, 1980, or paragraph 2.B(1)(A) of Airbus Industrie Service Bulletin Number A300-24-048 dated January 6, 1981, or later FAA approved revisions.

1. If any indication of splice overheat is found or any crimped splices are not correct, replace all affected feeder cable splices in accordance with Paragraph E, below, prior to the next flight or render the APU generator electrically inoperative and place an "APU GENERATOR INOP" placard in view of the flight crew until Paragraph E, below, is accomplished.

2. If incorrect insulating heat shrink sleeves are discovered, but no indications of splice overheat or incorrectly crimped splices are found, flight operations may be continued with inspections every 100 flights, until the replacement required by Paragraph C, below, is accomplished.

C. Replace all APU generator feeder crimped splices which have incorrect insulating heat shrink sleeves in accordance with Paragraph E, below, by July 1, 1981.

D. Replace all APU generator feeder crimped splices covered by B(1), above, in accordance with Paragraph E, below, by July 1, 1981.

E. Replace the splices and sleeves in accordance with Airbus Industrie AOT 24/80/102 dated October 30, 1980, or A300 Service Bulletin 24-048 dated January 6, 1981, or later FAA approved revisions.

F. Within the next 250 flights from the effective date of this amendment, unless already accomplished, inspect the APU generator feeder cable splices at stations 808VS and 160VS of manufacturer serial numbers (MSN) 002 through 119, except 029, 090, 112, and 117, in accordance with paragraph 2.b of Airbus Industrie Service Bulletin A300-24-050, dated March 31, 1981, or later FAA approved revisions.

1. If any indication of splice overheat is found, replace the defective splice(s) plus the corresponding splices of the same phase in accordance with paragraph G, prior to the next flight, or render the APU generator electrically inoperative and place an "APU GENERATOR INOP" placard in view of the flight crew until paragraph G below is accomplished.

2. If incorrectly crimped splices are found, replace the defective splices before December 31, 1981, in accordance with paragraph G below.

3. If no indications of overheating or incorrect crimping are found, no further action is required.

G. Replace the defective splices at stations 808VS and 160VS in accordance with Airbus Industrie Service Bulletin A300-24-049, dated March 31, 1981, or later FAA approved revisions.

H. Alternative methods of compliance with this AD which provide an equivalent level of safety may be utilized when they are approved by the Chief, Seattle Area Aircraft Certification Office, FAA Northwest Region.

The manufacturer's specifications and procedures identified and described in this directive are incorporated herein and made a part hereof pursuant to 5 U.S.C. 552(a)(1). All persons affected by this directive who have not already received these documents from the manufacturer may obtain copies upon request to Groupement d'Interet Economique, Airbus Industrie, Avenue Lucien, Servanty - B.P. No 33, 31700 Blagnac, France. These documents may also be examined at the FAA Northwest Region, 9010 East Marginal Way South, Seattle, Washington 98108.

Amendment 39-3996 became effective on December 30, 1980.

This amendment 39-4162 becomes effective July 22, 1981.

FOOTER:

Source: Official FAA Source ↗

Retrieved: Apr 8, 2026

Rights: U.S. Government Public Domain

This site is not affiliated with or endorsed by the FAA. Always verify with official sources.