AD 75-17-10
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Slingsby Aviation Ltd. | T.59.D Kestrel | Airworthiness Directives; Slingsby Model T59D Kestrel Gliders |
Unsafe Condition
Structural failure of the elevator actuator bracket P/N 59A-30-11 due to cracks in the inside welded corners.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Within 10 hours' time in service after the effective date, visually inspect the elevator actuator bracket P/N 59A-30-11 for cracks in the inside welded corners. If cracks are found, replace it with a machined aluminum bracket P/N 59A-03-8A/B/C before further flight. Discontinue inspections after installing the replacement bracket.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within the next 10 hours' time in service after the effective date of this AD and thereafter at intervals not to exceed 5 hours' time in service.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Slingsby Aviation Ltd. Model T59D Kestrel gliders certificated in all categories.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 8, 2026
Rights: U.S. Government Public Domain