AD 73-26-10

final rule
Data completeness: 70%

Airworthiness Directives; GENERAL DYNAMICS Models 22, 22M, and 30A Airplanes

AD Number
73-26-10
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Unknown
FR Citation
This information is not available.

Applicability

TypeManufacturerModelDetails
aircraft D & R Nevada LLC 22 Airworthiness Directives; GENERAL DYNAMICS Models 22, 22M, and 30A Airplanes
aircraft D & R Nevada LLC 22M Airworthiness Directives; GENERAL DYNAMICS Models 22, 22M, and 30A Airplanes
aircraft D & R Nevada LLC 30A Airworthiness Directives; GENERAL DYNAMICS Models 22, 22M, and 30A Airplanes

Unsafe Condition

Partial or total loss of generator power due to electric freon pack compressor motor failure.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Replace freon pack fuses with LPN 110 fuses for Model 22 airplanes within 50 hours' time in service. Modify freon pack compressor motor protectors per specified service bulletins for Models 22, 22M, and 30A within 300 hours' time in service. Equivalent installations may be approved by FAA upon submission of data.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within 50 hours' time in service after the effective date of this AD (for Model 22) and within 300 hours' time in service after the effective date (for Models 22, 22M, and 30A).

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

GENERAL DYNAMICS Models 22, 22M, and 30A airplanes with Hamilton Standard Electric Freon Packs Part Numbers 574056, 573970 (Model 22), 573971 (Model 22M), or 574057 (Model 30A).