AD 73-01-01

final rule

Airworthiness Directives; North American Rockwell - Aero Commander Model 100-180 and Model 100 Airplanes

AD Number
73-01-01
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Unknown
FR Citation
This information is not available.

Applicability

TypeManufacturerModelDetails
aircraft Dynac Aerospace Corporation Aero Commander 100 Airworthiness Directives; North American Rockwell - Aero Commander Model 100-180 and Model 100 Airplanes
aircraft Dynac Aerospace Corporation Aero Commander 100-180 Airworthiness Directives; North American Rockwell - Aero Commander Model 100-180 and Model 100 Airplanes

Unsafe Condition

Loss or reduction of engine power due to exhaust outlet blockage.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Inspect and repair or replace exhaust system components per FAA AC 43.13-1 Chapter 14, Section 3; install Aero Commander exhaust outlet guard Part Number SK1093 or equivalent approved by Southern Region Engineering and Manufacturing Branch, including drilling a 5/16 inch hole in the exhaust tailpipe and proper guard installation.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Prior to the next 25 hours time in service if the exhaust system has accumulated 500 or more hours time in service.

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

North American Rockwell Aero Commander Model 100-180 (Serial Numbers 068, 5001 through 5213) and Model 100 (Serial Numbers 251 through 360) retrofitted with Elano Corporation exhaust system P/N 099001.

AI-generated summary from the source AD text. Verify against the official source before acting.

Federal Register Abstract

Exhaust Outlet Blockage

Applicability Source Text

Show captured applicability text from the source AD
AD Final Rules - DRS_73-01-01.html
Copy URL
Print/Save as PDF
Document Versions
 Feedback
Details
AD Number:
73-01-01
Document Type:
AD Final Rules
Docket Number:
Unknown
Subject Heading:
Airworthiness Directives; North American Rockwell - Aero Commander Model 100-180 and Model 100 Airplanes
Subject:
Exhaust Outlet Blockage
Status:
Current
Citation:
This information is not available.
Citation Publish Date:
Effective Date:
12/29/1972
Make:
Dynac Aerospace Corporation
Model:
Aero Commander 100 | Aero Commander 100-180
Product Type:
Aircraft
Product Subtype:
Small Airplane
Affected AD:
Superseded AD:
Affected By:
Superseded By:
Service/Office:
Office of Primary Responsibility:
CFR Part Reference:
Part 39
Comments:
AIRWORTHINESS DIRECTIVES FINAL RULES: 73-01-01
CITATION:   This information is not available.

PAGE NUMBER:  

DOCKET NUMBER:   Unknown

AMENDMENT:   39-1578

AD NUMBER:   73-01-01

SUBJECT HEADING:   Airworthiness Directives; North American Rockwell - Aero Commander Model 100-180 and Model 100 Airplanes


ACTION:  

SUMMARY:  

DATES:   Effective December 29, 1972.

ADDRESSES:  

FOR FURTHER INFORMATION CONTACT:  

SUPPLEMENTARY INFORMATION:  

REGULATORY TEXT:  
73-01-01 NORTH AMERICAN ROCKWELL - AERO COMMANDER: Amdt. 39-1578. Applies to Model 100-180 Serial Numbers 068, 5001 through 5213 certificated in all categories. Model 100 Serial Numbers 251 through 360 and those Model 100's retrofitted with Elano Corporation exhaust system (NEE Turbo System Inc.) P/N 099001, certificated in all categories.

Compliance required as follows:

For exhaust systems which have accumulated 500 or more hours time in service accomplish the following prior to the next 25 hours time in service unless already accomplished.

To prevent loss or reduction of engine power due to exhaust outlet blockage accomplish the following:

(1) Inspect and repair or replace the exhaust system components in accordance with FAA Advisory Circular AC No. 43.13-1 Chapter 14, Section 3.

(2) Install Aero Commander exhaust outlet guard Part Number SK1093, or equivalent approved by Chief, Engineering and Manufacturing Branch, Southern Region, as follows:

(a) Remove muffler heater shroud.

(b) Drill 5/16 inch diameter hole through one wall of the exhaust tailpipe. Hole to be drilled on side of tail pipe closest to centerline of the airplane. Hole to be located 3 3/8 inches down from muffler outer wall.

(c) Install outlet guard Part Number SK1093 in hole and position so that guard does not touch any part of the inner muffler parts.

(d) Tighten guard around tailpipe and reassemble exhaust system.

Aero Commander Service Bulletin SB 1019 covers this same subject.

This amendment becomes effective December 29, 1972.

FOOTER:

Document Text

Show stored source text (verify against official source)
AD Final Rules - DRS_73-01-01.html
Copy URL
Print/Save as PDF
Document Versions
 Feedback
Details
AD Number:
73-01-01
Document Type:
AD Final Rules
Docket Number:
Unknown
Subject Heading:
Airworthiness Directives; North American Rockwell - Aero Commander Model 100-180 and Model 100 Airplanes
Subject:
Exhaust Outlet Blockage
Status:
Current
Citation:
This information is not available.
Citation Publish Date:
Effective Date:
12/29/1972
Make:
Dynac Aerospace Corporation
Model:
Aero Commander 100 | Aero Commander 100-180
Product Type:
Aircraft
Product Subtype:
Small Airplane
Affected AD:
Superseded AD:
Affected By:
Superseded By:
Service/Office:
Office of Primary Responsibility:
CFR Part Reference:
Part 39
Comments:
AIRWORTHINESS DIRECTIVES FINAL RULES: 73-01-01
CITATION:   This information is not available.

PAGE NUMBER:  

DOCKET NUMBER:   Unknown

AMENDMENT:   39-1578

AD NUMBER:   73-01-01

SUBJECT HEADING:   Airworthiness Directives; North American Rockwell - Aero Commander Model 100-180 and Model 100 Airplanes


ACTION:  

SUMMARY:  

DATES:   Effective December 29, 1972.

ADDRESSES:  

FOR FURTHER INFORMATION CONTACT:  

SUPPLEMENTARY INFORMATION:  

REGULATORY TEXT:  
73-01-01 NORTH AMERICAN ROCKWELL - AERO COMMANDER: Amdt. 39-1578. Applies to Model 100-180 Serial Numbers 068, 5001 through 5213 certificated in all categories. Model 100 Serial Numbers 251 through 360 and those Model 100's retrofitted with Elano Corporation exhaust system (NEE Turbo System Inc.) P/N 099001, certificated in all categories.

Compliance required as follows:

For exhaust systems which have accumulated 500 or more hours time in service accomplish the following prior to the next 25 hours time in service unless already accomplished.

To prevent loss or reduction of engine power due to exhaust outlet blockage accomplish the following:

(1) Inspect and repair or replace the exhaust system components in accordance with FAA Advisory Circular AC No. 43.13-1 Chapter 14, Section 3.

(2) Install Aero Commander exhaust outlet guard Part Number SK1093, or equivalent approved by Chief, Engineering and Manufacturing Branch, Southern Region, as follows:

(a) Remove muffler heater shroud.

(b) Drill 5/16 inch diameter hole through one wall of the exhaust tailpipe. Hole to be drilled on side of tail pipe closest to centerline of the airplane. Hole to be located 3 3/8 inches down from muffler outer wall.

(c) Install outlet guard Part Number SK1093 in hole and position so that guard does not touch any part of the inner muffler parts.

(d) Tighten guard around tailpipe and reassemble exhaust system.

Aero Commander Service Bulletin SB 1019 covers this same subject.

This amendment becomes effective December 29, 1972.

FOOTER:

Source: Official FAA Source ↗

Retrieved: Apr 8, 2026

Rights: U.S. Government Public Domain

This site is not affiliated with or endorsed by the FAA. Always verify with official sources.