AD 2019-08-12
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Bombardier | Various | Airworthiness Directives; Viking Air Limited (Type Certificate Previously Held by Bombardier, Inc.; Canadair Limited) Airplanes |
| aircraft | Bombardier | Various | Airworthiness Directives; Viking Air Limited (Type Certificate Previously Held by Bombardier, Inc.; Canadair Limited) Airplanes |
| aircraft | Viking | Various | Airworthiness Directives; Viking Air Limited (Type Certificate Previously Held by Bombardier, Inc.; Canadair Limited) Airplanes |
Unsafe Condition
parts manufactured with a higher percentage of fiberglass may cause wear and rupture of control cables due to greater friction if contacted, which could lead to reduced controllability of the airplane.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
repetitive detailed visual inspections of the aileron control system cables and flap interconnect system cables for damage or disconnected cables, corrective actions if necessary, and replacement of the Teflon parts in the aileron control systems, aileron/rudder interconnect, and aileron power unit beam.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 50 flight hours
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Viking Air Limited Model CL-215-6B11 (CL-215T Variant) and CL-215-6B11 (CL-415 Variant) airplanes.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain