AD 2009-24-15
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Socata | TBM 700 | Airworthiness Directives; SOCATA Model TBM 700 Airplanes |
| aircraft | Aviat | Various | Airworthiness Directives; SOCATA Model TBM 700 Airplanes |
Unsafe Condition
Elongation of bolts connecting power leads on R700 and R701 shunts, likely caused by incorrect tightening torque value. This could lead to heating, electrical arcing, or smoke, resulting in an in-flight loss of electrical power.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Replace the bolts of shunts R700 and R701 following DAHER-SOCATA Mandatory Service Bulletin SB 70-169, dated May 2009.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within the next 100 hours time-in-service after January 4, 2010, or within the next 12 months after January 4, 2010, whichever occurs first.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
SOCATA Model TBM 700 airplanes, serial numbers 434 through 502, and serial numbers 504 and 505, certificated in any category.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain
This site is not affiliated with or endorsed by the FAA. Always verify with official sources.