AD 2009-12-04
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Aviat | Various | Airworthiness Directives; Construcciones Aeronauticas, S.A. (CASA), Model C-212-CB, C-212-CC, C-212-CD, C-212-CE, C-212-CF, and C-212-DE Airplanes |
Unsafe Condition
Cracks have been reported in the inner shell of pitot/static pressure heads, supplied by Thales Optronics, which could operate outside their voltage specification. This could lead to incorrect readings on pressure instrumentation, potentially causing navigational errors.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Inspect the affected pitot tubes and static inlets for radial cracking around the top lip of the dynamic port. If cracks are found, replace the tubes with new part numbers 212-A0150-0001 and 212-A0150-0002.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 1 month or 300 flight hours after the effective date, whichever occurs first.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Construcciones Aeronauticas, S.A. (CASA) Model C-212-CB, C-212-CC, C-212-CD, C-212-CE, C-212-CF, and C-212-DE airplanes, all serial numbers, certificated in any category, with pitot tubes having part numbers 212-61105.1 or 212-61105.2 installed.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 4, 2026
Rights: U.S. Government Public Domain