AD 2006-09-08

final rule

Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

AD Number
2006-09-08
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. FAA-2006-24586
FR Citation
71 FR 24576
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system

Applicability

TypeManufacturerModelDetails
aircraft Bombardier Inc. CL-600-2B19 (Regional Jet Series 100) Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes
aircraft Bombardier Inc. CL-600-2B19 (Regional Jet Series 440) Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes

Unsafe Condition

Short circuit failures of certain alternating current (AC) contactors located in the avionics bay, which could result in arcing and consequent smoke or fire.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Modify the wiring on AC service bus contactor K4XA, in accordance with the Accomplishment Instructions of Bombardier Alert Service Bulletin A601R-24-121, dated April 18, 2006.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within 90 days after the effective date of this AD.

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) airplanes, serial numbers 7003 through 7990 inclusive and 8000 and subsequent; certificated in any category.

AI-generated summary from the source AD text. Verify against the official source before acting.

Federal Register Abstract

The FAA is adopting a new airworthiness directive (AD) for certain Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) airplanes. This AD requires modifying the wiring on an alternating current (AC) service bus contactor that is located in the avionics bay. This AD results from incidents of short circuit failures of certain AC contactors located in the avionics bay. We are issuing this AD to prevent short circuit failures of certain AC contactors, which could result in arcing and consequent smoke or fire.

Document Text

Show stored source text (verify against official source)
[Federal Register Volume 71, Number 80 (Wednesday, April 26, 2006)]
[Rules and Regulations]
[Pages 24576-24578]
From the Federal Register Online via the Government Publishing Office [<a href="http://www.gpo.gov">www.gpo.gov</a>]
[FR Doc No: 06-3990]


-----------------------------------------------------------------------

DEPARTMENT OF TRANSPORTATION

Federal Aviation Administration

14 CFR Part 39

[Docket No. FAA-2006-24586; Directorate Identifier 2006-NM-100-AD; 
Amendment 39-14579; AD 2006-09-08]
RIN 2120-AA64


Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional 
Jet Series 100 & 440) Airplanes

AGENCY: Federal Aviation Administration (FAA), Department of 
Transportation (DOT).

ACTION: Final rule; request for comments.

-----------------------------------------------------------------------

SUMMARY: The FAA is adopting a new airworthiness directive (AD) for 
certain Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) 
airplanes. This AD requires modifying the wiring on an alternating 
current (AC) service bus contactor that is located in the avionics bay. 
This AD results from incidents of short circuit failures of certain AC 
contactors located in the avionics bay. We are issuing this AD to 
prevent short circuit failures of certain AC contactors, which could 
result in arcing and consequent smoke or fire.

DATES: This AD becomes effective April 26, 2006.
    The Director of the Federal Register approved the incorporation by 
reference of a certain publication listed in the AD as of April 26, 
2006.
    We must receive comments on this AD by June 26, 2006.

ADDRESSES: Use one of the following addresses to submit comments on 
this AD.
    <bullet> DOT Docket Web site: Go to <a href="http://dms.dot.gov">http://dms.dot.gov</a> and follow 
the instructions for sending your comments electronically.
    <bullet> Government-wide rulemaking Web site: Go to <a href="http://www.regulations.gov">http://www.regulations.gov</a> and follow the instructions for sending your 
comments electronically.
    <bullet> Mail: Docket Management Facility; U.S. Department of 
Transportation, 400 Seventh Street, SW., Nassif Building, Room PL-401, 
Washington, DC 20590.
    <bullet> Fax: (202) 493-2251.
    <bullet> Hand Delivery: Room PL-401 on the plaza level of the 
Nassif Building, 400 Seventh Street, SW., Washington, DC, between 9 
a.m. and 5 p.m., Monday through Friday, except Federal holidays.
    Contact Bombardier, Inc., Canadair, Aerospace Group, P.O. Box 6087, 
Station Centre-ville, Montreal, Quebec H3C 3G9, Canada, for service 
information identified in this AD.

FOR FURTHER INFORMATION CONTACT: Wing Chan, Aerospace Engineer, Systems 
and Flight Test Branch, ANE-172, FAA, New York Aircraft Certification 
Office, 1600 Stewart Avenue, suite 410, Westbury, New York 11590; 
telephone (516) 228-7311; fax (516) 794-5531.

SUPPLEMENTARY INFORMATION:

Discussion

    Transport Canada Civil Aviation (TCCA), which is the airworthiness 
authority for Canada, notified us that an unsafe condition may exist on 
certain Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) 
airplanes. The TCCA advises that there have been seven incidents of 
short circuit failures of Tyco Hartman alternating current (AC) 
contactors 1K4XD and K4XA, located in the avionics bay on Model CL-600-
2B19 (Regional Jet Series 100 & 440) airplanes. In several cases, 
arcing, which initiated due to the presence of contaminants between the 
power studs, resulted in a fire, which continued until power to the 
contactor was interrupted, either by the wire being burned through or 
by the generator falling off-line. Short circuit failures of AC 
contactors, if not prevented, could result in arcing, which could 
result in smoke or fire.

Relevant Service Information

    Bombardier has issued Alert Service Bulletin A601R-24-121, dated 
April 18, 2006. The service bulletin describes procedures for modifying 
the wiring on AC service bus contactor K4XA. Accomplishing the actions 
specified in the service information is intended to adequately address 
the unsafe condition. The TCCA mandated the service bulletin and issued 
Canadian airworthiness directive CF-2006-07, dated April 19, 2006, to 
ensure the continued airworthiness of these airplanes in Canada.

[[Page 24577]]

FAA's Determination and Requirements of This AD

    This airplane model is manufactured in Canada and is type 
certificated for operation in the United States under the provisions of 
section 21.29 of the Federal Aviation Regulations (14 CFR 21.29) and 
the applicable bilateral airworthiness agreement. Pursuant to this 
bilateral airworthiness agreement, the TCCA has kept the FAA informed 
of the situation described above. We have examined the TCCA's findings, 
evaluated all pertinent information, and determined that we need to 
issue an AD for products of this type design that are certificated for 
operation in the United States.
    Therefore, we are issuing this AD to prevent short circuit failures 
of certain AC contactors which could result in arcing and consequent 
smoke or fire. This AD requires accomplishing the actions specified in 
the service information described previously.

FAA's Determination of the Effective Date

    An unsafe condition exists that requires the immediate adoption of 
this AD; therefore, providing notice and opportunity for public comment 
before the AD is issued is impracticable, and good cause exists to make 
this AD effective in less than 30 days.

Comments Invited

    This AD is a final rule that involves requirements that affect 
flight safety and was not preceded by notice and an opportunity for 
public comment; however, we invite you to submit any relevant written 
data, views, or arguments regarding this AD. Send your comments to an 
address listed in the ADDRESSES section. Include ``Docket No. FAA-2006-
24586; Directorate Identifier 2006-NM-100-AD'' at the beginning of your 
comments. We specifically invite comments on the overall regulatory, 
economic, environmental, and energy aspects of the AD that might 
suggest a need to modify it.
    We will post all comments we receive, without change, to <a href="http://dms.dot.gov">http://dms.dot.gov</a>, including any personal information you provide. We will 
also post a report summarizing each substantive verbal contact with FAA 
personnel concerning this AD. Using the search function of that Web 
site, anyone can find and read the comments in any of our dockets, 
including the name of the individual who sent the comment (or signed 
the comment on behalf of an association, business, labor union, etc.). 
You may review the DOT's complete Privacy Act Statement in the Federal 
Register published on April 11, 2000 (65 FR 19477-78), or you may visit 
<a href="http://dms.dot.gov">http://dms.dot.gov</a>.

Examining the Docket

    You may examine the AD docket on the Internet at <a href="http://dms.dot.gov">http://dms.dot.gov</a>, or in person at the Docket Management Facility office 
between 9 a.m. and 5 p.m., Monday through Friday, except Federal 
holidays. The Docket Management Facility office (telephone (800) 647-
5227) is located on the plaza level of the Nassif Building at the DOT 
street address stated in the ADDRESSES section. Comments will be 
available in the AD docket shortly after the Docket Management System 
receives them.

Authority for This Rulemaking

    Title 49 of the United States Code specifies the FAA's authority to 
issue rules on aviation safety. Subtitle I, section 106, describes the 
authority of the FAA Administrator. Subtitle VII, Aviation Programs, 
describes in more detail the scope of the Agency's authority.
    We are issuing this rulemaking under the authority described in 
subtitle VII, part A, subpart III, section 44701, ``General 
requirements.'' Under that section, Congress charges the FAA with 
promoting safe flight of civil aircraft in air commerce by prescribing 
regulations for practices, methods, and procedures the Administrator 
finds necessary for safety in air commerce. This regulation is within 
the scope of that authority because it addresses an unsafe condition 
that is likely to exist or develop on products identified in this 
rulemaking action.

Regulatory Findings

    We have determined that this AD will not have federalism 
implications under Executive Order 13132. This AD will not have a 
substantial direct effect on the States, on the relationship between 
the national government and the States, or on the distribution of power 
and responsibilities among the various levels of government.
    For the reasons discussed above, I certify that the regulation:
    1. Is not a ``significant regulatory action'' under Executive Order 
12866;
    2. Is not a ``significant rule'' under the DOT Regulatory Policies 
and Procedures (44 FR 11034, February 26, 1979); and
    3. Will not have a significant economic impact, positive or 
negative, on a substantial number of small entities under the criteria 
of the Regulatory Flexibility Act.
    We prepared a regulatory evaluation of the estimated costs to 
comply with this AD and placed it in the AD docket. See the ADDRESSES 
section for a location to examine the regulatory evaluation.

List of Subjects in 14 CFR Part 39

    Air transportation, Aircraft, Aviation safety, Incorporation by 
reference, Safety.

Adoption of the Amendment

0
Accordingly, under the authority delegated to me by the Administrator, 
the FAA amends 14 CFR part 39 as follows:

PART 39--AIRWORTHINESS DIRECTIVES

0
1. The authority citation for part 39 continues to read as follows:

    Authority: 49 U.S.C. 106(g), 40113, 44701.


Sec.  39.13  [Amended]

0
2. The Federal Aviation Administration (FAA) amends Sec.  39.13 by 
adding the following new airworthiness directive (AD):

2006-09-08 Bombardier, Inc. (Formerly Canadair): Amendment 39-14579. 
Docket No. FAA-2006-24586; Directorate Identifier 2006-NM-100-AD.

Effective Date

    (a) This AD becomes effective April 26, 2006.

Affected ADs

    (b) None.

Applicability

    (c) This AD applies to Bombardier Model CL-600-2B19 (Regional 
Jet Series 100 & 440) airplanes, serial numbers 7003 through 7990 
inclusive and 8000 and subsequent; certificated in any category.

Unsafe Condition

    (d) This AD results from incidents of short circuit failures of 
certain alternating current (AC) contactors located in the avionics 
bay. We are issuing this AD to prevent short circuit failures of 
certain AC contactors, which could result in arcing and consequent 
smoke or fire.

Compliance

    (e) You are responsible for having the actions required by this 
AD performed within the compliance times specified, unless the 
actions have already been done.

Modification

    (f) Within 90 days after the effective date of this AD, modify 
the wiring on AC service bus contactor K4XA, in accordance with the 
Accomplishment Instructions of Bombardier Alert Service Bulletin 
A601R-24-121, dated April 18, 2006.

Previous Actions Accomplished According to Modification Package

    (g) Actions accomplished before the effective date of this AD 
according to Bombardier Modification Summary Package IS601R2450-
0025, dated December 23, 2005,

[[Page 24578]]

are considered acceptable for compliance with the action specified 
in paragraph (f) of this AD.

Alternative Methods of Compliance (AMOCs)

    (h)(1) The Manager, New York Aircraft Certification Office, FAA, 
has the authority to approve AMOCs for this AD, if requested in 
accordance with the procedures found in 14 CFR 39.19.
    (2) Before using any AMOC approved in accordance with Sec.  
39.19 on any airplane to which the AMOC applies, notify the 
appropriate principal inspector in the FAA Flight Standards 
Certificate Holding District Office.

Related Information

    (i) Canadian airworthiness directive CF-2006-07, dated April 19, 
2006, also addresses the subject of this AD.

Material Incorporated by Reference

    (j) You must use Bombardier Alert Service Bulletin A601R-24-121, 
dated April 18, 2006, to perform the actions that are required by 
this AD, unless the AD specifies otherwise. The Director of the 
Federal Register approved the incorporation by reference of this 
document in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. 
Contact Bombardier, Inc., Canadair, Aerospace Group, P.O. Box 6087, 
Station Centre-ville, Montreal, Quebec H3C 3G9, Canada, for a copy 
of this service information. You may review copies at the Docket 
Management Facility, U.S. Department of Transportation, 400 Seventh 
Street, SW., Room PL-401, Nassif Building, Washington, DC; on the 
Internet at <a href="http://dms.dot.gov">http://dms.dot.gov</a>; or at the National Archives and 
Records Administration (NARA). For information on the availability 
of this material at the NARA, call (202) 741-6030, or go to <a href="http://www.archives.gov/federal_register/code">http://www.archives.gov/federal_register/code</a> --of--federal--regulations/
ibr--locations.html.

    Issued in Renton, Washington, on April 21, 2006.
Kalene C. Yanamura,
Acting Manager, Transport Airplane Directorate, Aircraft Certification 
Service.
[FR Doc. 06-3990 Filed 4-25-06; 8:45 am]
BILLING CODE 4910-13-P

Source: Official FAA Source ↗

Retrieved: Apr 4, 2026

Rights: U.S. Government Public Domain

This site is not affiliated with or endorsed by the FAA. Always verify with official sources.