AD 2006-02-03
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Raytheon | Hawker 800XP | Airworthiness Directives; Raytheon Model Hawker 800XP Airplanes |
Unsafe Condition
Installation of an incorrect fuse on the over-temperature switch on panel ZK in the rear equipment bay, which could result in a short circuit in the fuse and consequent heat damage to associated wiring and surrounding equipment, leading to smoke or fire on the airplane.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Inspect to determine if a 20-amp fuse is installed on the hydraulic over-temperature switch on panel ZK in the rear equipment bay. If a 20-amp fuse is installed, replace it with a 3-amp fuse. If any damage is found on associated terminals and wires, contact the FAA for applicable repair actions.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 50 flight hours or 30 days after the effective date of this AD, whichever is first.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Raytheon Model Hawker 800XP airplanes, certificated in any category, serial numbers 258541, 258556, and 258567 through 258713 inclusive.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 4, 2026
Rights: U.S. Government Public Domain