AD 2014-15-08
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Raytheon | Various | Airworthiness Directives; Beechcraft Corporation (Type Certificate Previously Held by Hawker Beechcraft Corporation; Raytheon Aircraft Company) Airplanes |
| aircraft | Beechcraft | Corporation | Airworthiness Directives; Beechcraft Corporation (Type Certificate Previously Held by Hawker Beechcraft Corporation; Raytheon Aircraft Company) Airplanes |
Unsafe Condition
Missing sealant on structural components in the fuel tank during the winglet installation process, which could result in a potential source of ignition in a fuel tank during a lightning strike, leading to an explosion or fire and subsequent in-flight breakup of the airplane.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Inspect for the presence of sealant on doubler plate edges, doubler plate rivets, and adjacent skin in the fuel vent surge tanks. Perform corrective actions if sealant is missing, in accordance with Hawker Beechcraft Service Bulletin SB 57-4112.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 600 flight hours or 12 months after the effective date of this AD, whichever occurs first.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Beechcraft Corporation (Type Certificate Previously Held by Hawker Beechcraft Corporation; Raytheon Aircraft Company) Model Hawker 800XP, 850XP, and 900XP airplanes, all serial numbers.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 4, 2026
Rights: U.S. Government Public Domain