AD 2005-25-07

final rule
Data completeness: 80%

Airworthiness Directives; Raytheon Aircraft Company, Model 390, Premier 1 Airplanes

AD Number
2005-25-07
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. FAA-2005-20712
FR Citation
70 FR 73351

Applicability

TypeManufacturerModelDetails
aircraft Raytheon Aircraft Company Airworthiness Directives; Raytheon Aircraft Company, Model 390, Premier 1 Airplanes

Unsafe Condition

The plastic cover over the air conditioning motor module was found melted or burned due to overheating of the electromagnetic interference-radio frequency interference (EMI-RFI) filter assembly located under the cover.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Replace the plastic cover over the air conditioning motor module with a metallic cover. Modify the air conditioning compressor motor module EMI-RFI filter located under the cover and reidentify the module part number. Limit future installations of the cover for the air conditioner and the air conditioning compressor motor module.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Before further flight

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Raytheon Aircraft Company, Model 390, Premier 1 airplanes.

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 4, 2026

Rights: U.S. Government Public Domain