AD 2010-17-15
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Raytheon | Various | Airworthiness Directives; Hawker Beechcraft Corporation (Type Certificate No. A00010WI Previously Held by Raytheon Aircraft Company) Model 390 Airplanes |
| aircraft | Beechcraft | Corporation Model 390 | Airworthiness Directives; Hawker Beechcraft Corporation (Type Certificate No. A00010WI Previously Held by Raytheon Aircraft Company) Model 390 Airplanes |
Unsafe Condition
Starter generators with deficient armature insulating materials may have been installed, potentially leading to the loss of operation of one or both starter generators and consequent loss of all non-battery electrical power.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Inspect both starter generators for affected serial numbers. Replace the starter generator(s) as specified based on the inspection results.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within the next 25 hours time-in-service (TIS) after September 29, 2010.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Hawker Beechcraft Corporation Model 390 airplanes, serial numbers RB-4 through RB-257, RB-259 through RB-265, RB-268, and RB-269.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain