AD 2005-20-14
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Airbus | A300 B4-620 | Airworthiness Directives; Airbus Model A300 B4-620, A310-304, A310-324, and A310-325 Airplanes |
Unsafe Condition
An ignition source in the auxiliary center tank (ACT), in combination with flammable fuel vapors, could result in a fuel tank explosion and consequent loss of the airplane.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Install fused adaptors between the external wiring harness and the in-tank wiring at the connectors on the fuel tank wall of the ACT, as specified in the applicable Airbus service bulletin.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 24 months after the effective date of the AD (November 10, 2005).
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Airbus Model A300 B4-620, A310-304, A310-324, and A310-325 airplanes, certificated in any category, equipped with one or more auxiliary center tank (ACT), except those on which Airbus Modification 12471 has been accomplished in production.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain