AD 2005-12-20
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | The | Lancair Company Model LC41-550FG | Airworthiness Directives; The Lancair Company Model LC41-550FG Airplanes |
Unsafe Condition
Cracks in the elevator torque tube assembly could lead to structural failure of the assembly.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Inspect the elevator torque tube assembly using both visual and dye penetrant methods. Replace the assembly with a modified one incorporating a steel doubler if cracks are found. Replace the modified assembly every 300 hours time-in-service or 18 months, whichever occurs first.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
The Lancair Company Model LC41-550FG airplanes.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain