AD 2005-10-15
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Airbus | A300 B4-600 | Airworthiness Directives; Airbus Model A300 B4-600, B4-600R, and F4-600R Series Airplanes, and Model C4-605R Variant F Airplanes (Collectively Called A300-600 Series Airplanes); and Model A310 Series Airplanes |
Unsafe Condition
Insufficient bonding of electrical bonding points in additional center tanks could result in electrical arcing inside the fuel tank, leading to the ignition of fuel vapors and a potential risk of explosion.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Modify the electrical bonding points of the additional center tanks (ACTs) by performing all actions specified in the Accomplishment Instructions of the applicable Airbus Service Bulletin.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 30 months after the effective date of this AD.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Airbus Model A300 B4-600, B4-600R, F4-600R, and C4-605R Variant F airplanes (collectively called A300-600 series airplanes), and Model A310 series airplanes, equipped with one or more additional center tanks (ACTs).
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 4, 2026
Rights: U.S. Government Public Domain