AD 2005-10-10
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Bombardier | Various | Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes |
Unsafe Condition
Potential failure of the horizontal stabilizer trim actuator (HSTA) secondary nut in conjunction with a latent failure of the HSTA primary load path could result in loss of horizontal trim control and consequent reduced controllability of the airplane.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Revise the Airworthiness Limitations section of the Instructions for Continued Airworthiness of the Canadair Regional Jet Maintenance Requirements Manual by incorporating new repetitive detailed inspections of the secondary load path indicator for the horizontal stabilizer trim actuator (HSTA).
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Before further flight
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) airplanes.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 4, 2026
Rights: U.S. Government Public Domain