AD 2005-05-16
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Airbus | A300 B4-622R and A300 F4-622R | Airworthiness Directives; Airbus Model A300 B4-622R and A300 F4-622R Airplanes |
Unsafe Condition
Lower guide fittings for the forward doors were found installed in the wrong positions at frames 14 and 16A, which could impede emergency evacuation and result in injury to passengers or crewmembers.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Perform a one-time detailed inspection to determine if lower guide fittings for the forward doors are installed in the correct positions. If not, re-install or replace the fittings as necessary before further flight.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 600 flight hours after the effective date of this AD.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Airbus Model A300 B4-622R airplanes, serial numbers 0797 to 0836; and Model A300 F4-622R airplanes, serial numbers 0805 to 0828, certificated in any category.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 4, 2026
Rights: U.S. Government Public Domain