AD 2005-01-08
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Airbus | A310 | Airworthiness Directives; Airbus Model A310 Series Airplanes; and Model A300 B4-600, B4-600R, and F4-600R Series Airplanes, and Model C4 605R Variant F Airplanes (Collectively Called A300-600) |
Unsafe Condition
Interference was noticed during production between two wire looms located near the door hinge of rack 107VU and the terminals of contactor 9DG, which could lead to possible short circuits in the wire looms supplying the fuel pump systems and the pitot probe heating system.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Relocate contactor 9DG located at rack 107VU and add protective sleeves to the two wire looms located at the door hinge of rack 107VU, in accordance with the Accomplishment Instructions of Airbus Service Bulletin A310-24-2087, Revision 01 (for Model A310 series airplanes) or Service Bulletin A300-24-6081, Revision 01 (for Model A300-600 series airplanes).
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 12 months after the effective date of this AD.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Airbus Model A310 series airplanes and Model A300 B4-600, B4-600R, and F4-600R series airplanes, and Model C4 605R Variant F airplanes (collectively called A300-600), as listed in Airbus Service Bulletins A310-24-2087, Revision 01, and A300-24-6081, Revision 01, dated December 18, 2003.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain