Unsafe Condition
Fretting and consequent arcing of the electrical harness of the integrated drive generator (IDG) at the pin-to-socket connector at the firewall, leading to intermittent interruption of electrical power supply.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Revise the airplane flight manual (AFM) to advise flightcrew of procedures associated with intermittent interruption of electrical power. Inspect for signs of arcing and perform necessary corrective actions. Optional terminating action includes replacing IDG harnesses with Cannon connectors on the nacelle side with harnesses having Souriau connectors.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 12 months of effective date
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Airbus Model A319-131, -132, and -133; A320-231, -232, and -233; and A321-131 and -231 series airplanes equipped with IAE V2500 engines and having Cannon connectors on the nacelle side of the firewall and Souriau connectors on the pylon side of the firewall.
AI-generated summary from the source AD text. Verify against the official source before acting.