AD 2003-19-04
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Bombardier | Various | Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 and 440) Airplanes |
Unsafe Condition
Chafing or other damage of the integrated drive generator (IDG) cables and the firewall separators of the pylon could result in electrical arcing, leading to an in-flight fire and/or loss of electrical power.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Inspect IDG cables and firewall separators for chafing or damage, and take corrective action if necessary. Identify the part number of the clamps holding the IDG cables; replace with new clamps if the part number is not TA121010R14-04.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within 550 flight hours or 2 months after the effective date, whichever occurs first.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Bombardier Model CL-600-2B19 (Regional Jet Series 100 and 440) airplanes, serial numbers 7003 through 7269 inclusive, certificated in any category.
AI-generated summary from the source AD text. Verify against the official source before acting.
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain