Airworthiness Directives; Airbus Model A300 B2 and B4; A300 B4-600, B4-600R, and F4-600R (Collectively Called A300-600); A310; A319; A320; A321; A330; and A340 Series Airplanes

AD Number
2003-03-04
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. 96-NM-179-AD
FR Citation
68 FR 4889

Applicability

TypeManufacturerModelDetails
aircraft Airbus A300 B2 and B4 Airworthiness Directives; Airbus Model A300 B2 and B4; A300 B4-600, B4-600R, and F4-600R (Collectively Called A300-600); A310; A319; A320; A321; A330; and A340 Series Airplanes

Unsafe Condition

Corrosion of the emergency actuator mechanism could cause failure of the emergency actuator striker mechanism on the passenger or emergency doors, leading to difficulty in opening the doors during an emergency evacuation.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Conduct repetitive visual inspections of the striker and guide valve of the passenger door actuators and certain emergency door actuators for corrosion, and take corrective action if necessary. Modify the striker mechanism of the emergency and passenger door actuators to terminate the repetitive inspections.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Before further flight

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Airbus Model A300 B2 and B4; A300 B4-600, B4-600R, and F4-600R (collectively called A300-600); A310; and certain Airbus Model A319; A320; A321; A330; and A340 series airplanes.

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 6, 2026

Rights: U.S. Government Public Domain

This site is not affiliated with or endorsed by the FAA. Always verify with official sources.