AD 2002-23-05

final rule
Data completeness: 70%

Airworthiness Directives; Cessna Model 750 Airplanes

AD Number
2002-23-05
Status
final_rule
Effective Date
Product Category
aircraft
Docket
Docket No. 99-NM-218-AD
FR Citation
67 FR 70003

Applicability

TypeManufacturerModelDetails
aircraft Cessna 750 Airworthiness Directives; Cessna Model 750 Airplanes

Unsafe Condition

The trip levels for the reset circuit breakers installed in the auxiliary hydraulic pump system and the King KHF 950 high frequency system(s) are too high, which can prevent corresponding high current remote control circuit breakers from tripping when excessive electrical loads are present.

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Replace the 5.0-ampere reset circuit breakers for the auxiliary hydraulic pump system and the King KHF 950 high frequency communication system(s) with 0.5-ampere reset circuit breakers, in accordance with Cessna Service Bulletin SB750-24-15, Revision 1, dated May 24, 1999.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within 90 days after the effective date of this AD.

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Cessna Model 750 airplanes, serial numbers 0001 through 0100 inclusive, certificated in any category.

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 6, 2026

Rights: U.S. Government Public Domain