87-23-01

final rule

Airworthiness Directives; Heath Tecna Service Bulletin 74000-25-007, dated March 6, 1987.

Unsafe Condition: Chafing of ceiling light wire bundles causing fire hazard.

Effective: Dec 10, 1987 Category: appliance Compliance: Within 60 days after the effective date of this AD

Why matched: Airworthiness Directives; Heath Tecna Service Bulletin 74000-25-007, dated March 6, 1987.

Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system