Airworthiness Directives; Taylorcraft Model F-19 Aircraft

Document Number
79-04-04
Type
ad
Published
N/A
Effective
February 23, 1979
Status
active
Rights
U.S. Government Public Domain

Abstract

Charging Circuit Fire Hazard

Document Text

AD Final Rules - DRS_79-04-04.html
Copy URL
Print/Save as PDF
Document Versions
 Feedback
Details
AD Number:
79-04-04
Document Type:
AD Final Rules
Docket Number:
Unknown
Subject Heading:
Airworthiness Directives; Taylorcraft Model F-19 Aircraft
Subject:
Charging Circuit Fire Hazard
Status:
Current
Citation:
This information is not available.
Citation Publish Date:
Effective Date:
02/23/1979
Make:
Taylorcraft 2000, LLC
Model:
F19
Product Type:
Aircraft
Product Subtype:
Small Airplane
Affected AD:
Superseded AD:
Affected By:
Superseded By:
Service/Office:
Office of Primary Responsibility:
CFR Part Reference:
Part 39
Comments:
AIRWORTHINESS DIRECTIVES FINAL RULES: 79-04-04
CITATION:   This information is not available.

PAGE NUMBER:  

DOCKET NUMBER:   Unknown

AMENDMENT:   39-3416

AD NUMBER:   79-04-04

SUBJECT HEADING:   Airworthiness Directives; Taylorcraft Model F-19 Aircraft

ACTION:  

SUMMARY:  

DATES:   Effective February 23, 1979.

ADDRESSES:  

FOR FURTHER INFORMATION CONTACT:  

SUPPLEMENTARY INFORMATION:  

REGULATORY TEXT:   79-04-04 TAYLORCRAFT AVIATION CORPORATION: Amendment 39-3416. Applies to Taylorcraft Model F-19 aircraft, serial numbers 001 through 112, 115 through 130, and 132.

Compliance is required as indicated. To prevent fire hazard in the charging circuit, accomplish the following:

This AD must be accomplished prior to next 50 hours time in service after the effective date of this AD or by July 1, 1979, whichever occurs first.

Remove the 12 gauge wire, identified as P/N -10, which connects the starter solenoid "battery terminal" with the master switch. Use Mil Spec MilC7078 or equivalent 8 gauge shielded wire, to fabricate a cable in the same manner as the 8 gauge cable from the alternator to the ammeter. Use appropriate wire terminals. Attach this cable to the ignition switch terminal of the ammeter. Route this 8 gauge wire through the opening in the firewall where the 12 gauge wire previously ran and attach it to the starter solenoid "battery terminal". (See attached wiring diagram.)

This amendment becomes effective February 23, 1979.