BOEING Model 707 and 720 Series Airplanes

Document Number
67-23-02
Type
ad
Published
N/A
Effective
September 10, 1967
Status
active
Rights
U.S. Government Public Domain

Abstract

Main Gear Downlock Rod

Document Text

AD Final Rules - DRS_67-23-02.html
Copy URL
Print/Save as PDF
Document Versions
 Feedback
Details
AD Number:
67-23-02
Document Type:
AD Final Rules
Docket Number:
Unknown
Subject Heading:
BOEING Model 707 and 720 Series Airplanes
Subject:
Main Gear Downlock Rod
Status:
Current
Citation:
This information is not available.
Citation Publish Date:
Effective Date:
09/10/1967
Make:
The Boeing Company
Model:
707-100 Long Body | 707-100B Long Body | 707-100B Short Body | 707-200 | 707-300 Series | 707-300B S...Show more
Product Type:
Aircraft
Product Subtype:
Large Airplane
Affected AD:
Superseded AD:
Affected By:
Superseded By:
Service/Office:
Office of Primary Responsibility:
CFR Part Reference:
Part 39
Comments:
AIRWORTHINESS DIRECTIVES FINAL RULES: 67-23-02
CITATION:   This information is not available.

PAGE NUMBER:  

DOCKET NUMBER:   Unknown

AMENDMENT:   39-462

AD NUMBER:   67-23-02

SUBJECT HEADING:   BOEING Model 707 and 720 Series Airplanes

ACTION:  

SUMMARY:  

DATES:   Effective September 10, 1967.

ADDRESSES:  

FOR FURTHER INFORMATION CONTACT:  

SUPPLEMENTARY INFORMATION:  

REGULATORY TEXT:   67-23-02 BOEING: Amdt. 39-462, Part 39, Federal Register August 11, 1967. Applies to Model 707 and 720 Series Airplanes, except 707-300B and -300C Series.

Compliance required within the next 7,000 hours' time in service after the effective date of this AD unless already accomplished.

To prevent explosion of fuel vapors in the fuel tanks as a result of lightning-induced ignition at the fuel tank vent outlet, accomplish one of the following, or an equivalent, approved by the Chief, Aircraft Engineering Division, FAA Western Region

(a) Install a flame and explosion suppression system in the fuel tank vent outlet system to prevent flame propagation through the vent system following ignition of vapor by lightning at the vent outlet; or

(b) Install an auxiliary vent tube with flame arrester, to the vent system surge tank to provide, during flight, continuous airflow inward through the existing outlet and outward through the protected auxiliary tube.

This amendment effective September 10, 1967.

FOOTER: