Airworthiness Directives; de Havilland Model DHC-6 Series Twin Otter Aircraft

Document Number
75-26-07
Type
ad
Published
N/A
Effective
December 17, 1975
Status
active
Rights
U.S. Government Public Domain

Abstract

Electrical Fire Hazards

Document Text

AD Final Rules - DRS_75-26-07.html
Copy URL
Print/Save as PDF
Document Versions
 Feedback
Details
AD Number:
75-26-07
Document Type:
AD Final Rules
Docket Number:
Unknown
Subject Heading:
Airworthiness Directives; de Havilland Model DHC-6 Series Twin Otter Aircraft
Subject:
Electrical Fire Hazards
Status:
Current
Citation:
This information is not available.
Citation Publish Date:
Effective Date:
12/17/1975
Make:
Viking Air Limited
Model:
DHC-6-1 | DHC-6-100 | DHC-6-200 | DHC-6-300
Product Type:
Aircraft
Product Subtype:
Small Airplane
Affected AD:
Superseded AD:
Affected By:
Superseded By:
Service/Office:
Office of Primary Responsibility:
CFR Part Reference:
Part 39
Comments:
AIRWORTHINESS DIRECTIVES FINAL RULES: 75-26-07
CITATION:   This information is not available.

PAGE NUMBER:  

DOCKET NUMBER:   Unknown

AMENDMENT:   39-2455

AD NUMBER:   75-26-07

SUBJECT HEADING:   Airworthiness Directives; de Havilland Model DHC-6 Series Twin Otter Aircraft

ACTION:  

SUMMARY:  

DATES:   Effective December 17, 1975.

ADDRESSES:  

FOR FURTHER INFORMATION CONTACT:  

SUPPLEMENTARY INFORMATION:  

REGULATORY TEXT:  
75-26-07 De Havilland: Amendment 39-2455. Applies to all DeHavilland Model DHC-6 Series Twin Otter aircraft certificated in all categories.

Compliance required as indicated to preclude the hazards of an electrical fire due to contact welding of the reverse current relay(s), Hartman part number A700AP or A700AAP.

1. For aircraft containing reverse current relays which have between 1000 to 2400 hours time in service since new or overhauled, or aircraft having reverse current relays which have less than 1000 hours time in service which have been used for cross generator engine starts, accomplish the following:

(A) Within the next 25 hours time in service, after the effective date of this AD, unless already accomplished,

(i) Remove the reverse current relays from the aircraft.

(ii) Examine relay for indications of overheat.

(iii) Inspect relay contact points under ten-power glass for signs of pitting, corrosion or other surface damage.

If any of the above conditions in 1(A) (ii) or 1(A) (iii) are present, replace relay with a serviceable unit before further flight.

2. This applies to aircraft containing reverse current relays with more than 2400 hours' time in service since new or overhauled.

(A) Unless already accomplished, inspect relays in accordance with Paragraph 1(A) of this AD

(B) Unless accomplished, within the previous 2400 hours' time in service after the effective date of this AD, conduct bench tests of reverse current relays within the next 100 hours' time in service after the effective date of this AD, in accordance with DeHavilland of Canada LTD. PSM 1-6-2 Part 7 or PSM 1-63-2 Chapter 24-30-00.

3. Within the next 10 flight hours, install the following placard in full view of the pilot:

"CROSS GENERATOR ENGINE STARTING IS PROHIBITED, EXCEPT IN AN EMERGENCY."

4. Following a flight for which an emergency cross generator engine start was made, within the next 25 hours' time in service, accomplish the inspection required by paragraph 1(A) of this AD.

5. If any inspection required by this AD is not accomplished within specified time above, airplane may be flown in accordance with FAR 21.197 to a base where inspections can be made.

This amendment is effective December 17, 1975.