BOEING Model 707 and 727 Series

Document Number
68-10-02
Type
ad
Published
N/A
Effective
May 11, 1968
Status
active
Rights
U.S. Government Public Domain

Abstract

Cargo Door and Escape Hatch Heater Blankets

Document Text

AD Final Rules - DRS_68-10-02.html
Copy URL
Print/Save as PDF
Document Versions
 Feedback
Details
AD Number:
68-10-02
Document Type:
AD Final Rules
Docket Number:
Unknown
Subject Heading:
BOEING Model 707 and 727 Series
Subject:
Cargo Door and Escape Hatch Heater Blankets
Status:
Current
Citation:
This information is not available.
Citation Publish Date:
Effective Date:
05/11/1968
Make:
The Boeing Company
Model:
707-100 Long Body | 707-100B Long Body | 707-100B Short Body | 707-200 | 707-300 Series | 707-300B S...Show more
Product Type:
Aircraft
Product Subtype:
Large Airplane
Affected AD:
Superseded AD:
Affected By:
Superseded By:
Service/Office:
Office of Primary Responsibility:
CFR Part Reference:
Part 39
Comments:
AIRWORTHINESS DIRECTIVES FINAL RULES: 68-10-02
CITATION:   This information is not available.

PAGE NUMBER:  

DOCKET NUMBER:   Unknown

AMENDMENT:   39-595

AD NUMBER:   68-10-02

SUBJECT HEADING:   BOEING Model 707 and 727 Series

ACTION:  

SUMMARY:  

DATES:   Effective May 11, 1968.

ADDRESSES:  

FOR FURTHER INFORMATION CONTACT:  

SUPPLEMENTARY INFORMATION:  

REGULATORY TEXT:  
68-10-02 BOEING: Amendment 39-595. Applies to Model 707 and 727 Series airplanes equipped with G. E. cargo door and escape hatch heater blankets P/N 8921165G1 through G7, Boeing P/N 10-60911-9 through -15, which have not been modified in accordance with General Electric Service Bulletin No. SB-2 dated October 4, 1967, including Modification No. 2 dated December 11, 1967.

Compliance required within the next 100 hours' time in service after the effective date of this AD, unless already accomplished.

To prevent fires in the cargo door and escape hatch heater blankets, accomplish the following:

1. Deactivate the "Passenger Cabin Blanket Heater" switch on the flight engineer's panel and placard switch "Inoperative", and deactivate the "Main Cargo Door Heater" circuit breaker or breakers on the pilot's overhead circuit breaker panel. Secure the circuit breaker(s) in the "OFF" position to prevent inadvertent activation, and placard the breaker(s) "Inoperative".

2. Deactivate the "Passenger Cabin Blanket Heater" switch on the flight engineer's panel and placard it "Inoperative" and deactivate the "Escape Hatch Heater" circuit breaker or breakers on the pilot's overhead circuit breaker panel. Secure the circuit breaker(s) in the "OFF" position to prevent inadvertent activation, and placard the circuit breaker(s) "Inoperative".

3. The heater blankets may be re-activated upon accomplishment of G.E. Service Bulletin No. SB-2 dated October 4, 1967, including Modification No. 2 dated December 11, 1967, or an equivalent approved by the Chief, Aircraft Engineering Division, Western Region.

This amendment becomes effective May 11, 1968.