Airworthiness Directives; VEST (ERCO) Model All Series 415 Aircraft and Models E and G

Document Number
54-26-02
Type
ad
Published
December 4, 1956
Effective
N/A
Status
active
Rights
U.S. Government Public Domain

Abstract

Control cable fraying

Document Text

AD Final Rules - DRS_54-26-02.html
Copy URL
Print/Save as PDF
Document Versions
 Feedback
Details
AD Number:
54-26-02
Document Type:
AD Final Rules
Docket Number:
Unknown
Subject Heading:
Airworthiness Directives; VEST (ERCO) Model All Series 415 Aircraft and Models E and G
Subject:
Control cable fraying
Status:
Current
Citation:
This information is not available.
Citation Publish Date:
12/04/1956
Effective Date:
Make:
Univair Aircraft Corporation
Model:
415-C | 415-CD | 415-D | 415-E | 415-G
Product Type:
Aircraft
Product Subtype:
Small Airplane
Affected AD:
Superseded AD:
Affected By:
Superseded By:
Service/Office:
AIR-700: Compliance & Airworthiness Division
Office of Primary Responsibility:
AIR-770: West Certification Branch
CFR Part Reference:
Part 39
Comments:
AIRWORTHINESS DIRECTIVES FINAL RULES: 54-26-02
CITATION:   This information is not available.

PAGE NUMBER:  

DOCKET NUMBER:   Unknown

AMENDMENT:  

AD NUMBER:   54-26-02

SUBJECT HEADING:   Airworthiness Directives; VEST (ERCO) Model All Series 415 Aircraft and Models E and G

ACTION:  

SUMMARY:  

DATES:  

ADDRESSES:  

FOR FURTHER INFORMATION CONTACT:  

SUPPLEMENTARY INFORMATION:  

REGULATORY TEXT:   54-26-02 VEST (ERCO): Applies to All Ercoupe Model 415 Series Aircraft and Models E and G.
Compliance required as indicated.

As a result of continual fraying and failure of control cables P/N 415-52148 or P/N 415-52172 in the control column assembly where they wrap around the control quadrant P/N 415-52130 or P/N 415-52122 the following inspection must be conducted until such time as a control quadrant is installed which is considered satisfactory by the Administrator:

After every 100 hours of operation remove control cables P/N 415-52148 or P/N 415-52172 and inspect them for any signs or indications of fraying or failure. Replace any cables which are not found to be in perfect condition. It is important that the cables be removed for the inspection since it has been found that inspection of the cables while in place will not always reveal defects. Also determine whether the aileron stop screw may be bearing on the cable, and, if so, it should be replaced by new stop bolt Erco P/N 415-52164-2.

Modifications approved by the FAA which are believed to eliminate the fraying difficulties are described in the following data:

1. Drawing No. 514, change "A", Met-Co-Aire Co., Fullerton Municipal Airport, Fullerton, Calif.;

2. Drawing No. New 101, change "A," J.V. Newman, Bates Aviation Inc., Hawthorne Municipal Airport, Hawthorne, Calif.

3. Drawing No. 12, dated November 1, 1954, Ed's Airmotive, 430 Windsor Way, Renton 2, Wash.;

4. Drawing No. 415-52137, change "1," dated February 21, 1955, Vest Aircraft Parts Division, Denver, Colo.

When one of these or an equivalent FAA-approved modification has been installed, the special 100-hour inspection outlined above may be dispensed with and normal inspection period resumed.

Rigging of controls should follow the process outlined in Ercoupe Service Department Bulletin No. 13 and Ercoupe Service Department Memorandum No. 35.

This supersedes AD 47-42-21.