Airworthiness Directives; MCDONNELL DOUGLAS DC-8-61F, -62F, -63F

Document Number
74-12-03
Type
ad
Published
N/A
Effective
June 6, 1974
Status
active
Rights
U.S. Government Public Domain

Abstract

Oxygen System

Document Text

AD Final Rules - DRS_74-12-03.html
Copy URL
Print/Save as PDF
Document Versions
 Feedback
Details
AD Number:
74-12-03
Document Type:
AD Final Rules
Docket Number:
Unknown
Subject Heading:
Airworthiness Directives; MCDONNELL DOUGLAS DC-8-61F, -62F, -63F
Subject:
Oxygen System
Status:
Current
Citation:
This information is not available.
Citation Publish Date:
Effective Date:
06/06/1974
Make:
The Boeing Company
Model:
DC-8-61F | DC-8-62F | DC-8-63F
Product Type:
Aircraft
Product Subtype:
Large Airplane
Affected AD:
Superseded AD:
Affected By:
Superseded By:
Service/Office:
Office of Primary Responsibility:
CFR Part Reference:
Part 39
Comments:
AIRWORTHINESS DIRECTIVES FINAL RULES: 74-12-03
CITATION:   This information is not available.

PAGE NUMBER:  

DOCKET NUMBER:   Unknown

AMENDMENT:   39-1858

AD NUMBER:   74-12-03

SUBJECT HEADING:   Airworthiness Directives; MCDONNELL DOUGLAS DC-8-61F, -62F, -63F

ACTION:  

SUMMARY:  

DATES:   Effective June 6, 1974.

ADDRESSES:  

FOR FURTHER INFORMATION CONTACT:  

SUPPLEMENTARY INFORMATION:  

REGULATORY TEXT:  
74-12-03 MCDONNELL DOUGLAS: Amendment 39-1858. Applies to DC-8-61F, -62F, -63F convertible freighter airplanes, certificated in all categories.

(1) For all aircraft in the passenger configuration, within twenty-four (24) hours of receipt of this telegram, or prior to further flight, whichever occurs later, unless already accomplished within the last 50 hours, perform the passenger oxygen system leak check per paragraph 1(a) DACO Alert Service Bulletin A35-25 Revision A dated May 10, 1974, or later FAA-approved revisions. If the oxygen system does not pass the leak check, inspect, repair and replace worn piping as required, and replace broken and missing supports prior to next flight; repeat leak test per DACO A.S.B. A35-25 Revision A, paragraph 1(a). At intervals not to exceed 50 flight hours visually inspect for worn oxygen piping, replace as necessary, and conduct the leak test per DACO A.S.B. A35-25 Revision A, paragraph 1(a) until the modifications described by DACO A.S.B. A35-25 Revision A, paragraph 1(b) have been accomplished. Within 300 hours time in service after initial leak check, secure all oxygen piping, per DACO A.S.B. A35-25 Revision A, paragraph 1(b).

(2) For aircraft in the full freighter configuration, prior to further flight after receipt of this telegram, close the oxygen hand shutoff valve on the passenger system and placard system inoperative until (1), above, is accomplished. Prior to conversion to passenger configuration, perform checks, repair, and modifications of (1) above. Paragraph 2, DACO A.S.B. A35-25 Revision A covers this subject.

This amendment becomes effective June 6, 1974, for all persons except those to whom it was made effective immediately by telegram dated May 11, 1974.


FOOTER:

Source: Official FAA Source ↗

Retrieved: Apr 8, 2026

Rights: U.S. Government Public Domain

This site is not affiliated with or endorsed by the FAA. Always verify with official sources.