Airworthiness Directives; Noorduyn Models Army UC-64, -64A, and -64B Airplanes

Document Number
46-23-06
Type
ad
Published
N/A
Effective
N/A
Status
active
Rights
U.S. Government Public Domain

Abstract

Surface Combustion Fuel Burning Heater

Document Text

AD Final Rules - DRS_46-23-06.html
Copy URL
Print/Save as PDF
Document Versions
 Feedback
Details
AD Number:
46-23-06
Document Type:
AD Final Rules
Docket Number:
Unknown
Subject Heading:
Airworthiness Directives; Noorduyn Models Army UC-64, -64A, and -64B Airplanes
Subject:
Surface Combustion Fuel Burning Heater
Status:
Current
Citation:
This information is not available.
Citation Publish Date:
Effective Date:
Make:
Noorduyn Aviation Ltd.
Model:
Army UC-64 | Army UC-64A | Army UC-64B
Product Type:
Aircraft
Product Subtype:
Small Airplane
Affected AD:
Superseded AD:
Affected By:
Superseded By:
Service/Office:
Office of Primary Responsibility:
CFR Part Reference:
Part 39
Comments:
AIRWORTHINESS DIRECTIVES FINAL RULES: 46-23-06
CITATION:   This information is not available.

PAGE NUMBER:  

DOCKET NUMBER:   Unknown

AMENDMENT:  

AD NUMBER:   46-23-06

SUBJECT HEADING:   Airworthiness Directives; Noorduyn Models Army UC-64, -64A, and -64B Airplanes

ACTION:  

SUMMARY:  

DATES:  

ADDRESSES:  

FOR FURTHER INFORMATION CONTACT:  

SUPPLEMENTARY INFORMATION:  

REGULATORY TEXT:   46-23-06 NOORDUYN: (Was Mandatory Note 2 of AD-2-578-1.) Applies Only to Army UC-64, -64A, and -64B Airplanes Equipped With Fuel-Burning Cabin Heaters.
Required at next periodic inspection.
The surface combustion fuel burning heater must be made inoperative by disconnecting and plugging the fuel line as near the engine as practicable unless the following modifications are accomplished:
(a) At fire resistant bulkhead must be installed between the heater and the belly fuel tank. A firewall having the fire-resistant qualities specified in CAR 3.624 will be acceptable.
(b) A fuel shutoff valve, controllable from the pilots' compartment must be installed in the fuel line between the engine and the heater.