Textron Aviation Inc. 400A Airworthiness Directives

Browse ADs indexed for this model. Applicability depends on your aircraft configuration.

Check your aircraft configuration

2014-21-06 Recurring

final rule

Airworthiness Directives; Beechcraft Corporation (Type Certificate Previously Held by Hawker Beechcraft Corporation; Raytheon Aircraft Company; Beech Aircraft Corporation) Airplanes

Unsafe Condition: Failure of the Acme nut threads in a pitch trim actuator (PTA).

Effective: Nov 28, 2014 Category: aircraft Compliance: Within 200 flight hours or 6 months after the effective date, whichever occurs first.

2014-15-15 Recurring

final rule

Airworthiness Directives; Beechcraft Corporation Airplanes

Unsafe Condition: Fatigue cracking in the horizontal stabilizer ribs, which could result in the failure of the horizontal stabilizer and loss of pitch control of the airplane.

Effective: Sep 5, 2014 Category: aircraft Compliance: Before the accumulation of 7,400 total flight hours or within 6 months after the effective date o...
Technical illustration of an aircraft flight control surface and actuator
Problem area Flight controls

2013-03-07

final rule

Airworthiness Directives; Hawker Beechcraft Corporation (Type Certificate Previously Held by Raytheon Aircraft Company; Beech Aircraft Corporation) Airplanes

Unsafe Condition: The wiring for the 5-volt direct current (DC) system is undersized and does not have adequate circuit protection for the smaller gauge wire.

Effective: Mar 19, 2013 Category: aircraft Compliance: Within 400 flight hours or 12 months after the effective date of this AD, whichever occurs first.
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system

2011-03-12

final rule

Airworthiness Directives; Hawker Beechcraft Corporation (Type Certificate Previously Held by Raytheon Aircraft Company; Beech Aircraft Corporation) Model 400A and 400T Airplanes

Unsafe Condition: Missing sealant on the left and right pylon firewall structures, which could result in flames penetrating the seams in the firewall between the engine and the aft fuselage, and a subsequent uncontr...

Effective: Mar 14, 2011 Category: aircraft Compliance: Within 200 flight hours or 12 months after the effective date of this AD, whichever occurs first.
Technical illustration of an aircraft turbine engine assembly
Problem area Engine

2009-07-02

final rule

Airworthiness Directives; Hawker Beechcraft Corporation Model MU-300-10 Airplanes and Model 400 and 400A Series Airplanes; and Raytheon (Mitsubishi) Model MU-300 Airplanes

Unsafe Condition: Incomplete latching of the existing adjustment mechanism and cracked reinforcement assemblies, which could result in sudden shifting of a flightcrew seat.

Effective: Apr 30, 2009 Category: aircraft Compliance: Within 200 hours time-in-service after March 13, 1996, for Hawker Beechcraft Model MU-300-10, Mod...

2007-24-01

final rule

Airworthiness Directives; Hawker Beechcraft Model 400A Series Airplanes

Unsafe Condition: Reports of undersized, and consequently unprotected, wire in the galley cabinets, which could lead to overheating of wire insulation and consequent fire or smoke in the airplane cabin.

Effective: Jan 2, 2008 Category: aircraft Compliance: Within 200 flight hours or 12 months after the effective date of this AD, whichever occurs first.
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system

2007-19-05

final rule

Airworthiness Directives; Hawker Beechcraft Model 400, 400A, and 400T Series Airplanes

Unsafe Condition: Loose attachment fasteners on the engine cowling panels, leading to panels peeling back or separating during flight, which could result in separation of a panel from the airplane and consequent dam...

Effective: Oct 23, 2007 Category: engine Compliance: Within 200 flight hours after the effective date of this AD.

2006-21-02

final rule

Airworthiness Directives; Raytheon (Beech) Model 400, 400A, and 400T Series Airplanes; and Raytheon (Mitsubishi) Model MU-300 Airplanes

Unsafe Condition: The buildup of ice on certain internal areas of the engine, such as the leading edges of the front inner compressor stator, could result in a dual-engine flameout.

Effective: Oct 25, 2006 Category: engine Compliance: Before further flight
Technical illustration of an aircraft turbine engine assembly
Problem area Engine

2006-15-16

final rule

Airworthiness Directives; Raytheon (Beech) Model 400 and 400A Series Airplanes

Unsafe Condition: Over-voltage conditions of the DC starter generator due to incompatibility between certain generator control units (GCUs), which could result in the loss of normal electrical power, damage to some ...

Effective: Sep 5, 2006 Category: aircraft Compliance: Within 200 flight hours or 6 months after the effective date of this AD, whichever occurs first.
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system

2004-22-02

final rule

Airworthiness Directives; Raytheon (Beech) Model MU-300-10, 400, 400A, and 400T Series Airplanes; and Raytheon (Mitsubishi) Model Beech MU-300 Airplanes

Unsafe Condition: Fuel leaking from components in the spoiler mixer bay, leading to the accumulation of fuel and/or fuel vapor in the spoiler mixer bay and/or the aft fuselage compartment, which could result in a fi...

Effective: Dec 1, 2004 Category: aircraft Compliance: Within 400 flight hours or 12 months after the effective date of this AD, whichever occurs first.

2004-03-35

final rule

Airworthiness Directives; Raytheon Model Beech 400A and 400T Series Airplanes

Unsafe Condition: Intermittent sticking of the relays on the A194 roll trim printed circuit board (PCB) in either the open or closed position, which could result in an out-of-trim condition requiring considerable co...

Effective: Mar 24, 2004 Category: aircraft Compliance: Before further flight.

2003-10-13

final rule

Airworthiness Directives; Raytheon Model Beech 400A and 400T Series Airplanes

Unsafe Condition: Leakage of oxygen from scored low-pressure oxygen tubing, which could result in lack of available oxygen for the flightcrew, or possible explosion or fire.

Effective: Jul 1, 2003 Category: aircraft Compliance: Before further flight.

2002-01-23 Recurring

final rule

Airworthiness Directives; Raytheon Model Beech 400, 400A, and 400T Series Airplanes; Model Beech MU-300-10 Airplanes; and Model Mitsubishi MU-300 Airplanes

Unsafe Condition: Cracking in the radius of the cutout of the aft flange of the left engine forward carry-through mount bracket, which could lead to failure of the engine mount and possible loss of the engine, and c...

Effective: Feb 14, 2002 Category: engine Compliance: Before further flight
Technical illustration of an aircraft turbine engine assembly
Problem area Engine

2001-24-11

final rule

Airworthiness Directives; Raytheon Model Beech 400, 400A, and 400T Series Airplanes, Model Mitsubishi MU-300 Airplanes, and Model Beech MU-300-10 Airplanes

Unsafe Condition: Loss of Indicated Airspeed (IAS) display due to water freezing in the pitot systems, leading to loss of altitude displays, pitch error, and adverse effects on connecting systems, which could result...

Effective: Dec 11, 2001 Category: aircraft Compliance: Before further flight

2001-20-07

final rule

Airworthiness Directives; Raytheon Model Beech 400A Series Airplanes

Unsafe Condition: Reports of electrical arcing at the battery and external power receptacle of the airframe ground in the aft fuselage due to a deficiency in the bus bar and washer design.

Effective: Nov 15, 2001 Category: engine Compliance: Within 50 flight hours after the effective date of this AD.
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system

2001-03-06 Recurring

final rule

Airworthiness Directives; Raytheon (Beech) Model MU-300, MU-300-10, 400, and 400A Series Airplanes

Unsafe Condition: Broken wire braiding in the bellows assembly of the bleed air supply tube assembly due to premature failure from loading.

Effective: Mar 22, 2001 Category: aircraft Compliance: Within 200 hours time-in-service.
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system

2000-25-04

final rule

Airworthiness Directives; Raytheon (Beech) Model MU-300, MU-300-10, 400, 400A, and 400T Series Airplanes

Unsafe Condition: Hydraulic fluid leakage from the B-nut area, which attaches a hydraulic tube to the anti-skid valve assembly, could lead to sudden loss of normal braking to the left wheel, causing an asymmetric br...

Effective: Jan 17, 2001 Category: aircraft Compliance: Within 200 flight hours after the effective date of this AD.

2000-09-12

final rule

Airworthiness Directives; Raytheon (Beech) Model 400A and 400T Series Airplanes

Unsafe Condition: Detachment or breakage of wires in the temperature switch assemblies of the wing ice protection system, which could result in the flightcrew not being advised of an over-temperature situation on th...

Effective: Jun 16, 2000 Category: aircraft Compliance: Within 200 flight hours after the effective date of this AD.

2000-05-06

final rule

Airworthiness Directives; Raytheon (Beech) Model 400A and 400T Series Airplanes

Unsafe Condition: Incorrect wiring of the engine fire extinguisher bottle squibs could cause failure of the engine fire extinguisher bottle to discharge or discharge of the wrong engine fire extinguisher bottle.

Effective: Apr 12, 2000 Category: aircraft Compliance: Within 50 flight hours (inspection) and within 200 flight hours (modification) after the effectiv...

99-21-26

final rule

Airworthiness Directives; Raytheon (Beech) Model 400, 400A, 400T, and MU-300-10 Airplanes

Unsafe Condition: Uncommanded nose-down pitch at certain flap settings during icing conditions due to inadequate ice protection system.

Effective: Nov 22, 1999 Category: aircraft Compliance: Before further flight

99-21-08

final rule

Airworthiness Directives; Raytheon (Beech) Model 400A Airplanes

Unsafe Condition: Chafing of the fuel tube assembly against the elevator control cable due to inadequate clearance between the components could result in fuel leakage from the fuel drain tube assembly and consequent...

Effective: Nov 12, 1999 Category: aircraft Compliance: Within 200 flight hours after the effective date (November 12, 1999)
Technical illustration of an aircraft flight control surface and actuator
Problem area Flight controls

98-06-30

final rule

Airworthiness Directives; Raytheon (Beech) Model 400, 400A, 400T, MU-300, and MU-300-10 Airplanes

Unsafe Condition: Cracking and consequent failure of the outflow/safety valves, which could result in rapid decompression of the airplane.

Effective: Apr 24, 1998 Category: aircraft Compliance: within 18 months after September 24, 1996 (for Model 400, 400A, MU-300-10 series) or within 18 mo...

96-25-03

final rule

Airworthiness Directives; Raytheon (Beech) Model 400A, 400T (Military T-1A), and 400T (Military TX) Series Airplanes

Unsafe Condition: Failure of locking tab washers on the flap roller attach bolt due to the absence of an inner tang could result in loss of roller attach nuts and flap roller, leading to flap loss under load limit c...

Effective: Jan 24, 1997 Category: aircraft Compliance: Prior to the accumulation of 200 hours time-in-service or within one year after the effective dat...

95-25-06

final rule

Airworthiness Directives; BEECH Model 400, 400A and 400T (Military T-1A) Airplanes

Unsafe Condition: The standby instrument lighting system's design causes the lighting for the standby instruments to dim to an unacceptable level when main electrical power is turned off.

Effective: Jan 16, 1996 Category: aircraft Compliance: Within 200 hours time-in-service after the effective date of this AD (January 16, 1996).

95-25-05

final rule

Airworthiness Directives; Beech Model 400A Airplanes

Unsafe Condition: Missing control push rod rivets could result in the disengagement of the push rod end from the push rod tube, leading to loss of roll control and subsequent reduced controllability of the airplane ...

Effective: Jan 16, 1996 Category: aircraft Compliance: Within 50 hours time-in-service after the effective date of this AD
Technical illustration of an aircraft flight control surface and actuator
Problem area Flight controls