67-01-04
final ruleAirworthiness Directives; SUPERIOR FLOW: Applies to All Aircraft with Continental E185, E225, O-470, IO-470 and Lycoming O-320, O-360, and IO-360 Engines Incorporating Superior Flow Oil Filters
Unsafe Condition: Failures of Superior Flow oil filter elements P/N US5003-27 and US5003-33 during cold weather starts and run-up, resulting in loss of oil and severe engine damage.