Airbus A321-213 Airworthiness Directives

Browse ADs indexed for this model. Applicability depends on your aircraft configuration.

Check your aircraft configuration

2011-16-03

final rule

Airworthiness Directives; Airbus Model A300 B4-600, A300 B4-600R, and A300 F4-600R Series Airplanes, and Model A300 C4-605R Variant F Airplanes (Collectively Called Model A300-600 Series Airplanes); Model A310 Series Airplanes; Model A318 Series Airplanes; Model A319 Series Airplanes; Model A320-211, -212, -214, -231, -232, and -233 Airplanes; Model A321 Series Airplanes; Model A330-200 and A330-300 Series Airplanes; and Model A340-200, A340-300, A340-500, and A340-600 Series Airplanes

Unsafe Condition: Batch of screws used to attach balance washers on the RAT turbine assembly or RAT turbine lower gear box assembly have not received the correct heat treatment, exposing them to potential fracture a...

Effective: Sep 9, 2011 Category: aircraft Compliance: Before further flight
Technical illustration of an aircraft turbine engine assembly
Problem area Engine

2010-02-05

final rule

Airworthiness Directives; Airbus Model A300, A300-600, A310, A318, A319, A320, A321, A330-300, A340-200, A340-300, A340-500, A340-600, and A380-800 Series Airplanes; and Model A330-201, A330-202, A330-203, A330-223, A330-243 Airplanes

Unsafe Condition: certain equipment of the flight deck door is defective, which could jeopardize flight safety.

Effective: Jan 18, 2011 Category: aircraft Compliance: Within 50 flight hours

2010-18-07

final rule

Airworthiness Directives; Airbus Model A318, A319, A320, and A321 Series Airplanes

Unsafe Condition: Structural failure of the elevators and consequent loss of control of the airplane.

Effective: Sep 9, 2010 Category: aircraft Compliance: Before further flight
Technical illustration of an aircraft flight control surface and actuator
Problem area Flight controls

2010-06-01

final rule

Airworthiness Directives; Airbus Model A319, A320, and A321 Series Airplanes

Unsafe Condition: Two incidents of near mid-air collision occurred on Airbus A320 Family aircraft during TCAS Resolution Advisory, due to lack of visibility of relevant information on the Primary Flight Display (PFD...

Effective: Apr 15, 2010 Category: aircraft Compliance: Within 60 months of the effective date (April 15, 2010)

2009-15-07

final rule

Airworthiness Directives; Airbus Model A319, A320, and A321 Series Airplanes

Unsafe Condition: An uncommanded steering condition during takeoff or landing, which could result in departure of the airplane from the runway.

Effective: Aug 25, 2009 Category: aircraft Compliance: Within 12 months of the effective date (August 25, 2009).

2009-15-02

final rule

Airworthiness Directives; Airbus Model A318, A319, A320, and A321 Airplanes

Unsafe Condition: A fracture of the gerotor pump of the A320 RAT may occur, leading to non-operation of the RAT in case of in-flight deployment. The non-deployment or non-pressurization of the RAT, associated with a...

Effective: Aug 19, 2009 Category: aircraft Compliance: Within 15 months after the effective date of the AD.
Technical illustration of an aircraft turbine engine assembly
Problem area Engine

2009-09-05

final rule

Airworthiness Directives; Airbus Model A318-100 and A319-100 Series Airplanes; A320-111 Airplanes; A320-200 Series Airplanes; and A321-100 and A321-200 Series Airplanes

Unsafe Condition: Electrical wire damage was found in the 103VU electrical panel due to contact between the hinge pin and the adjacent electrical wire harness.

Effective: Jun 4, 2009 Category: aircraft Compliance: Within 18 months after the effective date of this AD.
Technical illustration of an aircraft electrical generator and wiring assembly
Problem area Electrical system

2009-09-01

final rule

Airworthiness Directives; Airbus Model A318, A319, A320 and A321 Series Airplanes

Unsafe Condition: A bearing of the flap track No. 1 pendulum assembly has migrated out of position, potentially leading to separation of the bearing/flap track assembly and detachment of the affected flap surface fr...

Effective: May 6, 2009 Category: aircraft Compliance: Before further flight

2009-06-22

final rule

Airworthiness Directives; Airbus Model A318, A319, A320, and A321 Airplanes

Unsafe Condition: The cockpit door latch/striker assembly may have overheated, causing permanent internal damage prior to being electrically isolated by the internal thermal fuse. This condition, in case of a rapid ...

Effective: Apr 28, 2009 Category: aircraft Compliance: Within 8 months after the effective date of this AD.

2009-01-04

final rule

Airworthiness Directives; Airbus Model A318, A319, A320, and A321 Airplanes

Unsafe Condition: Loss of AC BUS 1, AC ESS BUS, and DC ESS BUS can result in the loss of 5 upper Display Units and integral lighting, leading to flight crew difficulty in reading standby instruments when DOME lights...

Effective: Feb 27, 2009 Category: aircraft Compliance: Within 42 months of the effective date (February 27, 2009).

2008-22-10

final rule

Airworthiness Directives; Airbus Model A318, A319, A320, and A321 Series Airplanes

Unsafe Condition: A cross connection of the fire extinguishing circuit system was identified. In case of fire, this cross connection will activate (discharge) the wrong forward or aft cargo compartment fire extingui...

Effective: Dec 19, 2008 Category: aircraft Compliance: Before further flight

2008-17-12

final rule

Airworthiness Directives; Airbus Model A318, A319, A320, and A321 Series Airplanes Equipped With Certain Northrop Grumman (Formerly Litton) Air Data Inertial Reference Units

Unsafe Condition: Failure of an ADIRU during flight, which could result in loss of one source of critical attitude and airspeed data and reduce the ability of the flightcrew to control the airplane.

Effective: Oct 2, 2008 Category: aircraft Compliance: Within 2 years after January 27, 2004 (the effective date of AD 2003-26-03)

2008-09-16

final rule

Airworthiness Directives; Airbus A318, A319, A320, and A321 Series Airplanes

Unsafe Condition: unsafe condition on an aviation product.

Effective: Jun 6, 2008 Category: aircraft

2008-05-12 Recurring

final rule

Airworthiness Directives; Airbus Model A318, A319, A320, and A321 Airplanes

Unsafe Condition: Wear damage to the inboard flap trunnions after incorporation of the terminating modification could lead to loss of flap surface control, potentially resulting in the flap detaching from the airpla...

Effective: Apr 16, 2008 Category: aircraft Compliance: Before further flight

2008-04-20

final rule

Airworthiness Directives; Airbus Model A319, A320, and A321 Series Airplanes

Unsafe Condition: unsafe condition on an aviation product.

Effective: Apr 3, 2008 Category: aircraft

2007-25-12

final rule

Airworthiness Directives; Airbus Model A318, A319, A320, and A321 Series Airplanes

Unsafe Condition: Hydraulic leak in the landing gear (LG) selector valve 40GA and/or the LG door selector valve 41GA.

Effective: Jan 14, 2008 Category: aircraft Compliance: Before further flight.
Technical illustration of an aircraft landing gear and wheel assembly
Problem area Landing gear

2007-17-14

final rule

Airworthiness Directives; Airbus Model A321 Series Airplanes

Unsafe Condition: Some operators have reported wheel corrosion, mainly under the heat-shield overlap area. In some cases a circular crack initiated from a corrosion pit. When the crack is initiated under the bead se...

Effective: Oct 2, 2007 Category: aircraft Compliance: Within 6 months after the effective date of this AD
Technical illustration of an aircraft landing gear and wheel assembly
Problem area Landing gear

2007-07-09

final rule

Airworthiness Directives; Airbus Model A318, A319, A320, and A321 Airplanes

Unsafe Condition: Electrical arcing in the center fuel tank due to inadequate bonding, which could result in an explosion of the center fuel tank and consequent loss of the airplane.

Effective: May 8, 2007 Category: aircraft Compliance: Within 78 months after the effective date of this AD.
Technical illustration of an aircraft fuel pump, filter, valve, and lines
Problem area Fuel system

2007-06-02 Recurring

final rule

Airworthiness Directives; Airbus Model A318, A319, A320, and A321 Airplanes

Unsafe Condition: Failure of the THSA's primary load path, which could result in latent (undetected) loading and eventual failure of the THSA's secondary load path and consequent uncontrolled movement of the horizon...

Effective: Apr 19, 2007 Category: aircraft Compliance: Within 10 months for the upper THSA attachment inspections, and within 20 months since first flig...

2006-20-03

final rule

Airworthiness Directives; Airbus Model A319, A320, and A321 Airplanes

Unsafe Condition: Girt bar disengagement from the floor fitting during deployment tests of slide rafts at the forward passenger doors.

Effective: Nov 2, 2006 Category: aircraft Compliance: Within 200 days after the effective date of this AD.

2006-12-22

final rule

Airworthiness Directives; Airbus Model A319, A320, and A321 Airplanes

Unsafe Condition: Three chord-wise cracks on the aft side of one carbon blade of a certain ram air turbine (RAT), which could result in reduced structural integrity of the carbon blade and consequent loss of the RAT...

Effective: Jul 21, 2006 Category: aircraft Compliance: Within 600 flight hours after the effective date
Technical illustration of an aircraft turbine engine assembly
Problem area Engine

2006-06-15

final rule

Airworthiness Directives; Airbus Model A318-100 Series Airplanes; Model A319-100 Series Airplanes; Model A320-111 Airplanes; Model A320-200 Series Airplanes; Model A321-100 Series Airplanes; and Model A321-200 Series Airplanes

Unsafe Condition: Air leakage through the water drain valves in the forward and aft cargo doors can reduce the concentration of fire extinguishing agent to below the level required to suppress a fire.

Effective: May 1, 2006 Category: aircraft Compliance: Within 14 months after the effective date of this AD.

2005-12-19

final rule

Airworthiness Directives; Airbus Model A319, A320, and A321 Series Airplanes

Unsafe Condition: Air leakage around the temperature sensor for the aft cargo compartment reduces the concentration of fire extinguishing agent below the level required to suppress a fire, potentially leading to an ...

Effective: Jul 29, 2005 Category: aircraft Compliance: Within 24 months after the effective date of this AD.

2005-10-04 Recurring

final rule

Airworthiness Directives; Airbus Model A319, A320, and A321 Series Airplanes

Unsafe Condition: Failure of the main landing gear (MLG) side-stay cuff lugs or down-lock spring attachments, which could result in improper down-lock of the MLG during a freefall extension, and possible collapse of...

Effective: Jun 15, 2005 Category: aircraft Compliance: Within 60 months from the first entry into service of the MLG, or before the accumulation of 9,00...
Technical illustration of an aircraft landing gear and wheel assembly
Problem area Landing gear

2004-25-11

final rule

Airworthiness Directives; Airbus Model A318, A319, A320, and A321 Series Airplanes

Unsafe Condition: Underlying safety issues involved in fuel tank explosions on several large transport airplanes. An ignition source for fuel vapor in the hydraulics bay could result in fire or explosion in the adja...

Effective: Jan 13, 2005 Category: aircraft Compliance: Within 19 months after the effective date of this AD (January 13, 2005).
Technical illustration of an aircraft fuel pump, filter, valve, and lines
Problem area Fuel system