AD Amdt-39-9887
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Fokker | F28 Mark 0100 | Airworthiness Directives; Fokker Model F28 Mark 0100 Series Airplanes |
Unsafe Condition
Incorrect routing and tension of the flight control lock cables and elevator control cables could result in inadvertent disconnection and consequent reduced controllability.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Conduct a one-time inspection to verify correct routing and tension of the flight control lock cables and elevator control cables. Reroute or adjust tension of the cables if necessary.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Fokker Model F28 Mark 0100 series airplanes modified at the factory where the inspection may not have been accomplished.
AI-generated summary from the source AD text. Verify against the official source before acting.