AD Amdt-39-9852
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Fokker | F28 Mark 0100 | Airworthiness Directives; Fokker Model F28 Mark 0100 Series Airplanes |
Unsafe Condition
Cracks were found in the flanges of the main hinge fittings of the horizontal stabilizer caused by higher than anticipated loads induced during thrust reverser operation.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Modify the thrust reverser doors in accordance with Fokker Service Bulletin SBF100-78-010, Revision 1. Replace Collins multifunction display units (MFDU) with new units as specified. Install a placard on the main instrument panel if MFDU replacement precedes thrust reverser door modification, and remove the placard after modification completion.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Prior to 15,000 total flight cycles or within 1 year after the effective date, whichever is later.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Fokker Model F28 Mark 0100 series airplanes with serial numbers 11244 through 11460 inclusive, 11463 through 11469 inclusive, 11471, 11474, 11476, 11478, and 11479.
AI-generated summary from the source AD text. Verify against the official source before acting.